Delta HMC07
Delta HMC07 is a handheld HMI and controller family combining a touchscreen, PLC logic and motion commands. It works with supported servo drives over DMCNET. Selection must consider control capacity, keys, the handwheel, safety contacts and connection assembly as well as screen size.
N500/510/511, N411 and N412/R412 must be distinguished. Legacy N5 models have 800 × 600 resolution; N411/N412 models have 800 × 480. For a handheld HMC07, inspect the hook/holder and cable exit. The panel-cutout approach used for fixed-mounted HMC08 devices cannot be transferred directly to this group.
HMC07-N500H52, N510H52 and N511H52
HMC07-N500H52, HMC07-N510H52, HMC07-N511H52: The shared instruction sheet specifies a 7-inch, 800 × 600 TFT, Ethernet, one serial COM channel, USB Host/Slave, SD/SDHC, DMCNET and dedicated high-speed RS-422 remote I/O. Check COM1’s RS-232/RS-422/RS-485 mode against the wiring diagram. F1–F10 function keys and an emergency-stop switch distinguish this generation.
N510 and N511 have different axis capacities. The catalogue identified by 17 February 2016 specifies up to 4 axes for HMC07-N510H52 and up to 12 axes for HMC07-N511H52. Inclusion in a shared N500/N510/N511 instruction sheet does not establish interchangeability based on display specifications alone. Verify the full model, existing project and DSP version together.
HMC07-N411: compact handheld generation
HMC07-N411H5C5 — 5 m and HMC07-N411H5CA — 10 m: 7-inch, 800 × 480 models with a handwheel, 15 function keys, DMCNET, RS-485, USB Slave and SD/SDHC. Ethernet is not provided. The 2016 catalogue lists up to 12 axes for both. Do not carry over USB Host or Ethernet specifications from the legacy N5 generation.
HMC07-N412 and R412 variants
HMC07-N412H5C5, HMC07-N412H5CA, HMC07-N412H5CF, HMC07-N412H5CK: The H5C group with 5 / 10 / 15 / 20 m cables, respectively. The catalogue identifies an MPG handwheel and three-position switch. The 2021 edition flags the 15 m and 20 m options for regional sales confirmation; their presence in a catalogue does not establish current stock.
HMC07-N412H555, HMC07-N412H55A, HMC07-N412H55F, HMC07-N412H55K: Listed in the 2019-coded N412 catalogue with 5 / 10 / 15 / 20 m cables, respectively. H55 models have no handwheel or three-position switch. The same cable length does not establish identical operator controls to an H5C model.
HMC07-R412H5C5 / HMC07-R412H5CA have a handwheel and three-position switch with 5 / 10 m cables. HMC07-R412H555 / HMC07-R412H55A provide 5 / 10 m cables without those controls. The 2021 catalogue identifies R412 for injection-machine pick-and-place applications. Physical key labels are English on N412 and Chinese/English on R412. Preserve the N/R and C/5 distinctions in the full code.
Common HMC07 specifications in the N412/R412 table include 7-inch 800 × 480, up to 12 axes, RS-485, DMCNET, USB Slave and SD/SDHC; Ethernet is not provided. The relevant catalogue uses the 12 model segment for the generation with nameplate-area protection. This does not establish automatic hardware or project equivalence with N411. Full codes come from the 2019 N412 catalogue PDF p.11 and 2021 PDF p.12.
Emergency stop and three-position switch distinctions
For N411 and H5C N412/R412, the catalogue describes the three-position switch as internal-register use, no external output signal. The handwheel also supplies internal control data. Their presence does not establish an independent externally wired safety output; verify the machine’s safety circuit separately.
The 2016 catalogue distinguishes one NO and one NC emergency-stop contact on N510/N511 from two NC contacts on N411; the 2021 N412 table also shows two NC contacts. Do not copy the old contact wiring or pinout when replacing a unit or cable. Within programming and HMC cables, match A0/C0 assemblies, power and safety conductors to the exact device instructions.
DOPSoft, communications and power
Use DOPSoft with support for the target HMC model. Preserve HMI screens, PLC logic in Ladder Editor, motion commands and servo settings together. The official Delta download centre and DOPSoft HMC Series manual record are reference points for version selection. The newest release is not automatically suitable for every older project. Keep an original copy before attempting conversion.
DMCNET, Ethernet and RS-485 serve different functions. Do not connect Ethernet to an N411/N412 DMCNET socket because it looks like RJ45. For communication peripheral units or Ethernet expansion modules, require documented support for the HMC model. Distinguish remote I/O modules from local I/O expansion by port type and addressing as well.
Nominal supply is in the 24 V DC class. The 2016 catalogue specifies 6 W and 0–40 °C for N411, and 8 W and 0–50 °C for N510/N511. The 2021 catalogue gives 6 W and 0–40 °C for N412. Account separately for peripherals and field loads. When checking HMI power supplies and power connections, measure voltage at the device end under load. Do not merge N411’s IP55 record and N412’s IP54 record into one family-wide rating.
Editor’s note
Photograph the complete model label. “HMC07, 7-inch” is insufficient. Axis limits differ between N510 and N511, while H5C and H55 operator controls differ. Put the full code in the replacement records.
Inspect frequent cable bending points, the exit gland, locking connector and signs of crushing first. Do not attempt to solve damage by adding an arbitrary extension; the assembly and termination must match the model.
Test the handwheel and three-position switch separately. With the machine in a safe state, monitor the corresponding register changes. A working register does not establish a correct wired emergency-stop circuit; do not bridge contacts for testing.
If the screen works but an axis does not, investigate DMCNET, servo alarms, station addresses and motion permissives separately. Back up screens, PLC logic and servo parameters before changing firmware or the project target.
For used units, check all touch areas, function keys, SD, USB and Ethernet where fitted in a controlled bench setup. One working menu is not a complete functional test. Motion testing requires a separate safe test arrangement.
Record retained values, clock settings and machine references before battery work. Battery types differ by generation: do not confuse the CR2450 listed for N411/N412 with the N5 generation’s CR2032. Verify retained settings before returning to automatic operation.
Related HMI families and documents
For display and interface generations, review DOP-A, DOP-AE, DOP-AS, DOP-B, DOP-W and DOP-100 documents. Handheld DOP-H07 and DOP-107H panels do not automatically replace HMC07’s PLC and motion-control functions.
TP text panels, TP04P and TP70P belong to different panel/control classes. Review HMI modules and accessories and starter kits within their documented scope.
Use Delta HMI PDF files and Delta PLC and HMI manuals to select documents. Return to Delta HMI families or browse available used Delta products.
Manufacturer documents and external references
HMC catalogue — DELTA_IA-HMI_HMC_C_EN_20160217 is a distributor-hosted manufacturer document; PDF pp.10–11 contain specifications and p.12 the code structure. 2019-coded HMC catalogue including N412 models PDF p.11 and the HMC catalogue dated 11 June 2021 PDF pp.11–12 support N412/R412 distinctions. Filenames and historical dates are not treated as definitive product-generation boundaries.
The N500/510/511 shared installation text mirror and N411 installation image/text mirror were consulted for exact-model connections. N411’s separate PDF download remained behind a verification screen; access to the text is not presented as a ready archived PDF.