Delta DVP-SS
Delta DVP-SS: Legacy 14-Point Slim PLC
Delta DVP-SS is a standalone PLC CPU with 8 digital inputs and 6 digital outputs within the Delta DVP PLC series range. It was used for sequencing, timing, counting and basic machine automation. Legacy SS documentation specifies 3,792 program steps and EEPROM program storage. It is not an auxiliary card or an I/O expansion module.
The CPU requires 24 V DC, with a specified input range of 20.4–28.8 V DC. Do not apply mains voltage to its 24 V DC supply terminals. Size the external power supply for the CPU, sensors and connected expansion units.
Distinguishing SS from SS2
This family includes the DVP14SS11R, DVP14SS11T, DVP14SS11R2 and DVP14SS11T2 headings. The final 2 in DVP14SS11R2/T2 does not identify an SS2 CPU. The DVP14SS211R/T codes belong to the separate Delta DVP-SS2 generation. Similar enclosures do not establish equal program memory, instruction support or pulse performance.
Relay and transistor outputs
R/R2 versions have relay outputs; T/T2 versions have NPN transistor outputs. Digital inputs can use sink/source wiring according to the S/S common connection. This input flexibility does not make the transistor outputs PNP. Check load voltage, current, common-terminal groups and temperature-related output limits.
The legacy SS programming manual describes two transistor pulse outputs, Y0 and Y1, up to 10 kHz. This capability does not apply to relay versions. High-speed counter frequency tables differ between some older documents and revisions, so match the CPU version to the relevant manual before choosing a counter mode.
Programming software
Delta WPLSoft is the established maintenance tool for writing programs, reading from the PLC, transferring projects and online monitoring on legacy SS controllers. It uses ladder and the instructions supported by the CPU. Delta ISPSoft can also be used with supported legacy SS targets; check the selected software release against the CPU and firmware. Do not select SS2 for an SS project. Functions offered by newer CPUs cannot automatically be used on an old SS.
Delta COMMGR manages communication for ISPSoft. Configure an RS232 connection with the correct COM port, then select that driver in ISPSoft. Configure WPLSoft communication through its own communication menu. See Delta PLC software for the roles of these tools.
Programming cable and communication ports
Program transfer uses the PLC’s 8-pin Mini-DIN RS-232 port. The manufacturer’s instruction sheet lists DVPACAB2A30 and DVPACAB230 cables. DVPACAB2A30 is a 3 m cable connecting a computer’s 9-pin serial port to the PLC. If the computer has no serial port, use a suitable USB-to-RS-232 adapter with its driver.
The DVP-SS has no built-in USB or Ethernet port. A computer’s USB connection therefore requires an external adapter, rather than an ordinary USB cable connected directly to the PLC. A USB-to-TTL adapter is not an RS-232 substitute. Refer to Delta PLC cables and Delta PLC accessories for connection hardware.
The series also provides RS-485 field communication. Match station address, baud rate, data bits, parity, stop bits and protocol when connecting an HMI or drive. If communication fails, check wiring, COM assignment and parameters first; do not reset a working machine controller before backing it up.
Expansion, analog functions and replacement
The SS CPU has no built-in analog inputs or outputs. Analog measurement, analog control and temperature applications require compatible Delta DVP expansion modules. X/Y addressing is octal: X10 follows X7. Check the module order together with the addresses used in the existing program.
Other families include Delta DVP-SA, Delta DVP-SC, Delta DVP-SX, Delta DVP-SA2 and Delta DVP-SE. Select according to the required I/O, analog functions, communication and program migration. Compare mechanical layout, common terminals and output technology before installing a different CPU.
Editor’s Note
Read the complete nameplate before buying a used SS. DVP14SS11R2 and DVP14SS211R look similar, but the position of one digit identifies a different generation.
POWER and RUN indicators are not sufficient evidence of a healthy PLC. Check program readout, input changes in online monitoring and each output with a suitable test load.
If an output LED turns on but the load does not operate, measure the output common and load supply first. Worn or welded relay contacts and failed transistor outputs are possible checks, not diagnoses established from the LED alone.
Measure the 24 V supply under operating load as well as at idle. Loose terminals or a deteriorated power supply can resemble a PLC fault.
Back up the program, required retained registers and communication settings before downloading a new project. A project backup does not necessarily contain every machine setting.
For serial faults, verify the cable, RS-232 electrical interface, adapter driver and COM settings first. Disconnect power before board repair; do not begin troubleshooting by erasing the program.
PDF documents and related topics
Use Delta DVP PLC files for series documents. Refer to the SS sections of the DVP-PLC programming manual for legacy instructions and device addressing. An SS2 manual should not be used as a direct substitute for an SS manual.