Delta DVP-SC

Delta DVP-SC PLC series

Delta DVP-SC is a legacy Slim PLC CPU series in the Delta DVP range, developed for high-speed pulse I/O and positioning. It executes the machine program in its own CPU and can handle pulse commands for servo/step drives, high-speed counting and homing applications.

DVP-SC models and main specifications

DVP12SC11T uses a 24 V DC supply and has 8 digital inputs and 4 transistor outputs. Inputs are X0–X5 and X10/X11; outputs are Y0/Y1 and Y10/Y11. The designated high-speed terminals are X10/X11 and Y10/Y11. Program memory is in the 8K class, specified precisely as 7,920 steps in the instruction sheet.

DVP12SC11R is listed with 8 inputs and 4 relay outputs in Delta's 2007 Russian catalogue. The detailed high-speed output specifications in the SC instruction sheet apply to the T model; relay contacts on the R model cannot provide the same high-frequency pulses. Check the complete model code and terminal arrangement when replacing a unit.

The specified supply range for DVP12SC11T is 20.4–28.8 V DC, with 4 W maximum consumption. It has no built-in analog I/O. Later Delta programming manuals identify SC as discontinued in 2013, so maintenance work requires legacy documentation that actually includes SC.

Programming software

DVP-SC can be programmed with WPLSoft and ISPSoft. WPLSoft is the Windows programming tool named in the SC instruction sheet. SC also appears in ISPSoft's DVP support and function tables. Select the SC CPU type and preserve the original project's engineering tool and version.

For ISPSoft, create an appropriate serial channel in COMMGR. COMMGR is not the program editor, and a USB converter's driver is a separate component. Establishing a connection does not imply support for modifying the program while the CPU is in RUN. See Delta PLC software for installation and version information.

Programming cable and communication

The standard programming connection uses COM1 RS-232. The instruction sheet lists DVPACAB2A30, an approximately 3 m cable with a 9-pin female D-sub PC connector and an 8-pin mini-DIN PLC connector. See Delta PLC programming cables for cable options.

For a computer without a serial port, use PC USB → USB-to-RS-232 converter with its driver installed → DVPACAB2A30 → PLC COM1. DVP-SC has no built-in USB or Ethernet port. A USB-to-TTL adapter is not an RS-232 converter.

COM2 RS-485 is available for field communication. The instruction sheet specifies slave operation on COM1, master/slave operation on COM2, and ASCII/RTU support. Match station address, baud rate, data bits, parity and stop bits to the existing application. Do not alter a working PLC's port settings merely to try a connection.

High-speed inputs, pulse outputs and bandwidth

X10 and X11 are the special high-speed counting inputs; Y10 and Y11 are the fast transistor outputs used for positioning. The instruction sheet gives up to 100 kHz under suitable individual-channel conditions. This limit does not apply indiscriminately to every input, counting mode or simultaneous two-output operation.

Delta's technical note specifies 130 kHz total bandwidth for SC pulse output and counting. For simultaneous two-output operation with V1.2/V1.4 firmware, it gives limits of 60 kHz for Y10 and 40 kHz for Y11, with Y11 running below Y10. Calculate the application limits using the actual firmware and instruction.

Positioning instructions include DDRVI, DDRVA and DZRN. Match pulse/direction or A/B signalling, drive input circuitry and commons. Do not assume the ordinary output load rating also applies unchanged to fast pulse terminals.

Expansion and legacy compatibility

The SC instruction sheet describes connection to suitable DVP-SS family expansion units. When choosing Slim digital, Slim analog or Slim temperature modules from the DVP expansion range, verify SC support, module revision and the supply budget. Delta's legacy SC/SA table gives a 236 I/O limit, which must also be considered.

Editor's Note

Do not replace an SC simply because another Delta PLC has twelve I/O points. Its high-speed terminal addresses matter, and matching the point count alone will not preserve the original wiring or program behaviour.

Back up the program, retained registers and communication settings first. Photograph the model and firmware label too; guessing a code during maintenance creates avoidable errors.

If operation becomes erratic after power-up, check the 24 V supply under load. Inspect sensor, drive and PLC commons before treating a supply or wiring fault as a CPU failure.

Touching a contact by hand is not a complete high-speed counter test. Use a suitable signal of known frequency for counting and an oscilloscope for the pulse outputs, with machine motion safely prevented.

Take the battery-backed memory seriously. Make a backup before servicing the battery and verify the correct battery type and replacement procedure. Do not apply another PLC family's rechargeable-battery advice to this legacy unit.

For a used PLC, test more than the RUN indicator: check normal I/O, X10/X11 counting, Y10/Y11 pulses, both communication ports and data retention after a controlled power cycle.

PDF manuals

Use our Delta DVP PLC files page for documentation. The existing DVP-SC hardware, programming summary and wiring instruction sheet is the English 2006 edition. More documents are available under Delta PLC and HMI manuals; a DVP title alone does not establish SC coverage.

Related topics

For other Slim families of the same period, see DVP-SA, DVP-SX and DVP-SV. For comparison with later generations, see DVP-SS2 and DVP-SV2. Compare high-speed terminal addresses, output technology, instructions and expansion hardware together.

Delta PLC main page · All DVP series · Second-hand Delta equipment · DVP PDF files

External references

Delta DVP-SC Instruction Sheet, 2006 — English manufacturer document, archive copy · Delta DVP technical catalogue, 2007 — Russian, R/T model table · Delta technical note — SC bandwidth and programming cable · ISPSoft User Manual, 2021 — English