Delta DOP-AS

Delta DOP-AS is a legacy HMI family combining a touchscreen and physical keys with serial communication to PLCs and other controllers. DOP-AS35THTD, DOP-AS38BSTD, DOP-AS38BSTD-W, DOP-AS57BSTD and DOP-AS57CSTD share 320 × 240 resolution, while display size, colour technology, backlighting and COM3 interfaces differ.

There is no built-in Ethernet port. Three COM channels does not mean three identical independent connectors. Read the AS35/AS38 and AS57 port tables separately. The native project-software generation is Screen Editor / ScrEdit 1.05.

DOP-AS models and display differences

DOP-AS35THTD: 3.5-inch TFT, 65,536 colours, 320 × 240, with LED backlighting. 118.8 × 92.8 mm cutout and 140.8 × 104.8 × 44.8 mm external dimensions. HQ10 specifies 8 MB SDRAM and 3.36 W panel consumption. Its colour TFT is the main display distinction from the blue STN AS38 with the same cutout.

DOP-AS38BSTD: 3.8-inch STN, eight shades of blue, 320 × 240, with LED backlighting. 118.8 × 92.8 mm cutout and 140.8 × 104.8 × 44.8 mm external dimensions. HQ10 specifies 4 MB SDRAM and 2.64 W. Matching AS35 resolution does not provide the same colour palette or application appearance.

DOP-AS38BSTD-W: the white-case AS38BSTD variant. The catalogue and Screen Editor manual distinguish W = white; no suffix = grey. It remains a 3.8-inch blue STN panel with a 118.8 × 92.8 mm cutout. W is not a communication or Ethernet option; do not derive additional AS ordering codes from this suffix.

DOP-AS57BSTD: 5.7-inch STN, eight shades of blue, 320 × 240, with documented CCFL backlighting. 172.4 × 132.4 mm cutout; HQ10 gives 184.1 × 144.1 × 47 mm external dimensions, 16 MB SDRAM and 5.28 W. Its COM3 electrical interface also differs from AS38.

DOP-AS57CSTD: 5.7-inch colour STN, 256 colours, 320 × 240, with CCFL backlighting and a 172.4 × 132.4 mm cutout. The 2008 catalogue has separate AS57BSTD and AS57CSTD columns; the HQ10 Turkish table groups them as AS57B(C)STD. CSTD identifies colour STN, not the TFT technology used by AS35THTD.

Keys, memory and USB

The reviewed AS models provide four user-defined physical keys and one system key. Do not describe all five as freely programmable function keys. Preserve their machine functions as well as the touchscreen interface when replacing a panel.

HQ10 specifies 2 MB total NOR Flash, divided into 1 MB system and 1 MB user application, with 128 KB backup memory listed separately. Total Flash, available application capacity and SDRAM are different quantities. Check actual project capacity before adding large images, fonts or recipes.

There is one USB Host 1.1 and one USB Client 1.1. Client is the PC connection; Host serves supported flash drives or printers. The AS table lists no SM-card slot or expansion interface. Do not assign the SM-card or expansion hardware of DOP-AE to DOP-AS.

AS35 and AS38: shared COM1/COM3 RS-232 connector

AS35THTD and AS38BSTD(-W) share one DB9 connector between COM1 and COM3. COM1 is RS-232, COM2 is RS-422/RS-485, and COM3 is RS-232. Select the software mode together with the pins used for the second RS-232 channel.

HQ10 identifies COM1 pin 2 as RXD1, pin 3 as TXD1 and pin 5 as GND. In dual RS-232 mode, COM3 uses pin 7 TXD2 and pin 8 RXD2. In single-channel mode, pins 7/8 serve RTS/CTS. Enabling RS-232 hardware flow control prevents COM3 use. A matching DB9 plug alone does not establish cable compatibility.

The AS35/AS38 COM2 terminal block provides R−, R+, T−, T+ and G. For RS-485, the sheet specifies R+ joined to T+ as D+ and R− joined to T− as D−. This description applies to the AS35/AS38 terminal table and must not be copied directly to AS57’s different mode table. Confirm the connector viewing direction from the manufacturer drawing.

AS57: COM3 is also RS-422/RS-485

AS57BSTD and AS57CSTD list COM1 RS-232 and COM2/COM3 RS-422/RS-485. The AS35/AS38 COM3 RS-232 cable cannot substitute for this interface. The AS57BSTD two-terminal-block table separately shows dual RS-485, dual RS-422 and RS-422 flow-control modes.

AS57 COM2 and COM3 cannot operate independently when RS-422 flow control is selected. Assess how the selected mode uses another channel. The AS57CSTD specification confirms the interface class; verify its actual terminal layout and hardware revision against the device drawing.

Match the complete panel, controller driver, baud rate, parity and address when selecting programming and HMC cables or communication peripheral units. Availability of an Ethernet expansion module for another HMI family does not establish AS support.

Screen Editor / ScrEdit projects and backups

Delta’s 30 April 2007 manual explicitly identifies ScrEdit for DOP-A, DOP-AE and DOP-AS. Its installation and program menus use Screen Editor 1.05.xx. Preserve the working panel project together with the editor release, panel OS/firmware and controller communication settings.

A newer DOPSoft or DIAScreen release does not establish programming compatibility with legacy AS hardware. Opening a project in another application and programming the AS panel require separate verification. For migration, check the target, screen objects, palette, macros, recipes and all four user-key functions.

Use the official Delta download centre and manufacturer support for installers, providing the full model and existing Screen Editor version. Historical Windows requirements and download links are not guarantees of current OS compatibility or download availability. Work on a project copy.

The Screen Editor manual specifies FAT32 for USB flash drives. Verify capacity, device compatibility and automatic project-update functions against the panel/software release. Copying log files does not prove that the editable source project has also been backed up.

Power, mounting and document editions

The HQ10 English/Turkish table specifies 24 V DC, −10% / +15% and 0–50 °C operation. Panel consumption is 3.36 W for AS35, 2.64 W for AS38 and 5.28 W for AS57B(C). Add USB peripheral loads. Select shared power supplies against the isolated-supply requirement, total demand and cable voltage drop.

The earlier Russian HQ05 translation prints a different upper supply tolerance. Do not combine that entry with HQ10’s English/Turkish value to create a wider operating range. Use the device label and manufacturer instruction for the actual revision. Issue dates alone do not establish the production start or end of the entire family.

Small models use a 118.8 × 92.8 mm cutout; AS57 uses 172.4 × 132.4 mm. The relevant HQ10 drawings specify +1/0 mm cutout tolerance and 1.6–3.0 mm enclosure-panel thickness. These are not bezel dimensions. Review the gasket, fasteners, cooling and rear cable clearance under mounting and power connections.

The catalogue’s IP65/NEMA4 front-face protection is not an all-round waterproof rating for rear connections. Documents list one CR2032 3 V lithium backup battery. Preserve the project, required retained data and clock settings before battery service or system changes.

Editor’s note

Start with label and rear-connector photographs and a working-project backup. AS35 and AS38 may fit the same opening, but one is colour TFT and the other blue STN. Check colours and objects when rebuilding the interface on a replacement.

For a communication fault, check COM3’s electrical standard first. It is RS-232 on AS38 and RS-422/485 on AS57. Flow control may disable another channel; do not work from memorised wire colours.

For a very dim display, separate contrast, backlighting and supply faults. AS38 uses LED backlighting; AS57 uses CCFL. Ageing CCFL lamp and driver circuits can involve high voltage; isolate power and use appropriate measurement and service methods.

Test touch response at edges and corners, all four user keys and the system key. Mechanical key action and the correct machine response are separate checks. Record contaminated membranes, cracked bezels and damaged seals.

Do not stop at finding files on a flash drive: verify an editable source matching the panel. If a USB device is not recognised, check supported formatting and software first. Avoid unidentified OS/firmware files on a working system.

Preserve recipes, alarms and communication settings before battery service or migration. Under controlled conditions, verify clock/data retention after a power cycle, PLC addresses and key functions. A boot screen alone does not complete machine commissioning.

Related HMI families and documents

Assess the related legacy DOP-A and DOP-AE hardware separately. Compare later DOP-B, DOP-W and DOP-100 families by projects and ports as well as cutouts. DOP-H07 and DOP-107H are handheld panels.

HMC07 and HMC08 include motion-control functions; TP text panels, TP04P and TP70P have their own panel/control structures. Naming similarity does not establish software or accessory compatibility with DOP-AS.

Select remote I/O, digital I/O expansions, starter kits and HMI modules/accessories against explicit compatibility documents. Use Delta HMI PDF files and Delta PLC and HMI manuals for documents. Return to Delta HMI families or browse available used Delta products.

Manufacturer documents and external references

The DOP-A/AE/AS HQ10 quick-start guide — 12 July 2010, 5011649610 contains English, Turkish and two Chinese sections. Turkish occupies PDF pp.16–29; AS specifications are on pp.25–26 and port tables on pp.21–22. The hosting address’s 2012 date is not the printed edition date.

The DOP-A/AE/AS connection manual — March/April 2007, 2007PDD23000007 contains printed chapter pp.1-1–1-136; the shared AS connector table is PDF p.3. Use the model-specific HQ10 tables for AS57 details rather than applying the old general AS drawing universally.

The 2008 DOP/TP catalogue shows AS38/AS57B/AS57C on PDF p.9 and W case coding on p.14. The 30 April 2007 ScrEdit manual covers software and AS38 hardware. The 20 August 2007 HQ05 Russian regional translation is a historical supplementary source. Links point to third-party archives of manufacturer documents; differing translation entries have not been merged into a new common specification.