Delta DOP-AE
Delta DOP-AE is a legacy Screen Editor-era HMI family with expansion support, combining touchscreens, physical keys and serial communication. Its 5.7, 8, 9.4 and 10.4-inch models do not share one display technology. Check the screen, cutout, COM mode, memory and fitted expansion module together.
AE does not mean built-in Ethernet. Suitable hardware uses the DOP-EXLNHJ1AE expansion module for Ethernet. Three COM channels do not mean three identical independent sockets: COM2/COM3 operation depends on the selected mode.
5.7-inch models: BSTD, GSTD and CSTD
DOP-AE57BSTD: 5.7-inch STN, eight shades of blue, 320 × 240. 172.4 × 132.4 mm cutout; the catalogue gives 184.1 × 144.1 × 47 mm external dimensions. It uses CCFL backlighting and is not a colour TFT model.
DOP-AE57GSTD: 5.7-inch FSTN, 16 grey levels, 320 × 240. It has a 172.4 × 132.4 mm cutout and CCFL backlighting. Its greyscale FSTN display differs from BSTD’s blue STN.
DOP-AE57CSTD: 5.7-inch colour STN, 256 colours, 320 × 240. The cutout is 172.4 × 132.4 mm, with CCFL backlighting. CSTD is not a 65,536-colour TFT panel; preserve the legacy project’s palette and graphics.
DOP-AE57BSTD-W, DOP-AE57GSTD-W and DOP-AE57CSTD-W are the corresponding white-case versions. Unsuffixed cases are described as grey. W is not an Ethernet or communication option. Retain these documented codes without deriving hypothetical W variants for other sizes.
The 5.7-inch AE models provide four user-defined keys and one system key. The 2008 catalogue specifies 4 MB total Flash: 1 MB system / 3 MB user, 16 MB SDRAM and 512 KB backup memory. Total Flash, available project space and temporary memory are different quantities.
8, 9.4 and 10.4-inch models
DOP-AE80THTD: 8-inch TFT, 65,536 colours, 640 × 480; 231.4 × 166.4 mm cutout and 243.1 × 178.1 × 52.4 mm external dimensions. HQ10 specifies six user keys plus one system key, 32 MB SDRAM and 14 W panel consumption. Its colour TFT still uses CCFL backlighting.
DOP-AE94BSTD: 9.4-inch blue STN, eight shades, 640 × 480; 285.2 × 210.2 mm cutout. The catalogue shows 11 user keys plus one system key; the 2007 manual specifies 16 MB SDRAM. Its display and keys differ from the 10.4-inch TFT despite the related cutout size.
DOP-AE10THTD1: 10.4-inch TFT, 65,536 colours, 640 × 480; 285.2 × 210.2 mm cutout. HQ10 gives 297.1 × 222.1 × 51.1 mm external dimensions, seven user keys plus one system key, 32 MB SDRAM and 15 W. Preserve the final 1.
DOP-AE10THTD also appears in the 2007 ScrEdit manual and Delta’s May 2008 bulletin. DOP-AE80THTD1 appears with this exact suffix in the July 2014 eRemote support table. These entries have not been silently changed to AE10THTD1 or AE80THTD. In particular, a support-table entry alone does not assign AE80THTD’s complete hardware specification to AE80THTD1.
COM1 and the shared COM2/COM3 connector
DOP-AE specifies COM1 RS-232 and COM2/COM3 RS-232/RS-422/RS-485. COM2 and COM3 can use different pins on the same DB9 connector. Single-channel, dual RS-232, dual RS-422 and dual RS-485 modes do not use the same pin functions.
The 2007 AE connection table identifies, in dual RS-232 mode, COM2 pin 2 RXD and pin 3 TXD; COM3 pin 7 TXD and pin 8 RXD, with pin 5 GND. In single-channel mode, pins 7/8 can serve RTS/CTS. Match both the operating mode and the manufacturer connector view.
HQ10 states that COM2 RS-422 hardware flow control prevents COM3 use. Three COM labels therefore do not establish independent simultaneous operation for every connection. Check controller drivers, baud rate, parity and station addresses when choosing programming and HMC cables or communication peripheral units.
Ethernet and DOP-AE expansion modules
DOP-EXLNHJ1AE is the AE Ethernet expansion module; the 2008 catalogue specifies 10Base-T / 100Base-TX. Its catalogue supply is 5 V, 1 A provided by the HMI. The panel’s 24 V supply is not a voltage to apply to this module interface. See HMI Ethernet expansion modules.
DOP-EXIO14RAE: 8 digital inputs plus 6 relay outputs. DOP-EXIO28RAE: 16 digital inputs plus 12 relay outputs. Treat these as digital I/O expansions, separately from remote I/O and HMC network/module arrangements.
DOP-EXPM110 is a 25-pin parallel-printer expansion. An AE-family listing under HMI modules and accessories does not prove support for every panel revision or module combination. Verify the fitted code, mechanical connection and Screen Editor configuration together.
eRemote support requires the model and module
The eRemote manual dated 10 July 2014 lists DOP-AE57BSTD, DOP-AE57GSTD, DOP-AE57CSTD, DOP-AE80THTD1 and DOP-AE10THTD1, with DOP-EXLNHJ1AE required. AE94BSTD and W case codes are not separately listed; support must not be automatically extended to them.
eRemote displays and controls the HMI screen over Ethernet; it does not replace the Screen Editor source-project editor. Verify firmware, eRemote release, module and network settings together. Preserve the working project before firmware changes. Historical Windows requirements do not establish current OS compatibility.
Screen Editor, SM cards and USB
The manufacturer’s DOP-A/AE/AS manual identifies ScrEdit / Screen Editor 1.05.xx. Installing a newer DOPSoft or DIAScreen release does not establish programming compatibility with legacy AE hardware. Record the existing editor, project target, panel OS/firmware and PLC settings.
The 5.7-inch AE tables list SM-card support but do not show a built-in USB Host. Check the Host/Client and card hardware of AE80 and larger models separately. Do not rename an SM card as an SD/SDHC card. Card access, USB storage and Ethernet transfer are different functions.
There are edition differences in AE10 SM-card entries: the 2008 catalogue and 2007 manual do not use identical card indications, while HQ10 marks card support across its AE columns. Likewise, larger models retain 8 MB total Flash, but the older manual divides it into 1 MB system / 7 MB user and HQ10 into 2 MB system / 6 MB user. Do not promise one usable capacity or card arrangement without checking the revision.
Use the official Delta download centre and manufacturer support for installers. Convert a project copy, checking physical keys, palette, macros, alarm history, recipes and communication-loss behaviour. Opening a file does not establish download support for the old panel or full compatibility with a new one.
Power and mechanical replacement
The reviewed English manufacturer documents specify 24 V DC, −10% / +15%: 21.6–27.6 V DC. Add the panel, expansion and peripheral loads when choosing shared power supplies. A different upper tolerance in the older Russian translation must not widen the rating; use the label and revision-specific instruction.
Cutouts are 172.4 × 132.4 mm for the 5.7-inch group, 231.4 × 166.4 mm for AE80 and 285.2 × 210.2 mm for AE94/AE10. These are nominal openings, not bezel sizes. Obtain tolerances, enclosure thickness and rear module clearance from the model drawing. Review the gasket and module projection under mounting and power connections.
Documents specify 0–50 °C operation and IP65/NEMA4 front-face protection. This does not make rear serial connections and expansion modules waterproof. Preserve the project and required retained data before servicing the listed CR2032 3 V lithium battery.
Editor’s note
Start with the label, fitted rear module, cable photographs and a project backup. AE does not establish Ethernet hardware. Record the fitted module, W case suffix and final 1 as carefully as the panel model.
Blue, grey and colour 5.7-inch models may fit the same opening. Do not treat BSTD, GSTD and CSTD as the same display technology. Check the readability of alarm and state colours when moving a colour project to a monochrome display.
Check which mode controls the COM2/COM3 pins. Pins serving RTS/CTS in one mode become the second channel’s TX/RX in another. Loss of COM3 after enabling flow control is not automatically a failed port.
Separate supply, contrast, CCFL lamp and backlight-driver faults. TFT does not necessarily mean LED backlighting. Account for high voltage in CCFL circuits, isolate power and use suitable service methods.
Distinguish SM from SD cards and USB Client from USB Host. Verify that backups open, match the target and include required recipes. Have a recovery source before battery or firmware service.
Test the touchscreen, every user key, system key, used serial channel and fitted module separately on a used unit. An eRemote image does not validate the whole machine. Check I/O, recipes, alarms and communication-loss behaviour under controlled conditions after migration.
Related HMI families and documents
DOP-A and DOP-AS are different hardware families from the same legacy software period. Compare later DOP-B, DOP-W and DOP-100 panels by ports, cutouts and projects together. DOP-H07 and DOP-107H are handheld panels.
HMC07 and HMC08 have motion-control roles; TP text panels, TP04P and TP70P have their own control structures. Apply the same model/software checks to HMI starter kits.
Use Delta HMI PDF files and Delta PLC and HMI manuals for document selection. Return to Delta HMI families or browse available used Delta products.
Manufacturer documents and external references
The 2008 DOP/TP catalogue provides AE displays/memory on PDF p.10, modules on p.13 and W coding on p.14. The 30 April 2007 ScrEdit manual includes key counts on p.70, specifications on pp.294–297 and drawings on pp.299–302. Use this edition for AE94 and the older AE10THTD code.
The 12 July 2010 HQ10 quick-start guide — includes Turkish covers serial modes on PDF pp.21–22 and AE80/AE10 specifications/cutouts on pp.27–28. The March/April 2007 connection manual has the shared AE connector table on PDF p.2. These are third-party-hosted manufacturer documents.
The DOP eRemote user manual — 10 July 2014 provides the support list and Ethernet-module requirement on PDF p.5. Delta’s May 2008 HMI bulletin also confirms AE10THTD and the four expansion modules. Issue dates have not been treated as the production start or end of the whole family.