Delta DOP-107H

Delta DOP-107H is a handheld operator-panel family with a 7-inch, 800 × 480, LED-backlit TFT display. HS serial and HE Ethernet variants differ by MPG handwheel, function keys, cable length and connector. DOP-107H is not a complete ordering code.

Delta’s July 2019 discontinuation entry concerns the older DOP-H07, with DOP-107H as its suggested successor. It does not identify DOP-107H as discontinued. Verify the replacement hardware, cable and project together.

HS, HE, 42, 46 and 47ZD variants

DOP-107HS42x: RS-422/RS-485 serial communication, without Ethernet. It provides SD/SDHC and 15 function keys, without an MPG. Delta Türkiye’s manufacturer list explicitly identifies DOP-107HS42A as the 10-metre model without a handwheel.

DOP-107HS46x: RS-422/RS-485, without Ethernet, with MPG, SD/SDHC and 15 function keys. The listed DOP-107HS46A has a 10-metre cable and handwheel. Use the exact model’s instruction; do not describe the HS port as RS-232 or Ethernet.

DOP-107HE42x: one 10/100 Mbps Ethernet connection, without a serial port. It provides SD/SDHC and 15 function keys, without an MPG. DOP-107HE42A is explicitly listed as the 10-metre Ethernet version.

DOP-107HE46x: one 10/100 Mbps Ethernet connection, MPG, SD/SDHC and 15 function keys. The listed DOP-107HE46A has a 10-metre cable and handwheel. Its PLC connection standard differs from HS46 despite a similar display.

DOP-107HE42xZM: Ethernet, a 25-pin D-SUB cable connector and no MPG. DOP-107HE46xZM: Ethernet, 25-pin D-SUB and MPG. Do not equate ZM with the standard cable termination: supply, LAN, emergency-stop and three-position-switch circuits use different pins of one connector.

DOP-107HE47xZD: Ethernet, MPG, SD/SDHC, 25-pin D-SUB and 21 function keys. Do not reuse a 15-key model’s mapping without checking the project. The 9 July 2021, 7H02 instruction separately identifies this group.

Here x is the manufacturer’s cable-length placeholder, not a literal ordering-code character. The length field uses 5 for 5 metres and A for 10 metres, before ZM/ZD where fitted. Do not generate model codes by combining every series, keypad and connector option. Use the label and an explicit full-code record.

Hardware, memory and handheld use

The 7H02 instruction specifies ARM Cortex-A8 at 800 MHz, 256 MB Flash ROM, 256 MB RAM and 32 KB non-volatile memory. Active display area is 154.08 × 85.92 mm; touch sensing is four-wire resistive. Flash, working RAM and retained-data space are different capacities.

Overall dimensions are 257.4 × 170.3 × 71.8 mm, including the projecting emergency-stop switch and hook. English and Chinese tables give approximately 750 g excluding the cable. This is not a panel cutout. Review grip, hanging point, moving cable route and bending areas.

The instruction specifies 0–40 °C operation and IP54. Inspect the SD/SDHC cover, cable entry and seals on a used unit. Do not copy cutouts or front-face ratings from fixed DOP-100 panels to the entire handheld enclosure.

Emergency stop, three-position switch and MPG

Standard-cable HS/HE models show two normally closed emergency-stop contacts — 2 NC. The ZM and ZD connector groups show 1 NO + 1 NC. These are different safety-circuit contact arrangements. Compare the exact panel and machine circuit instead of relying on wire colours.

The rear three-position operation switch is specified with one NO contact. Fitting emergency-stop or enabling hardware does not establish a machine-wide safety category. Verify external contact wiring and testing against the machine design and appropriate safety controller/relay; screen communication does not replace contact verification.

The 42 groups have no MPG. Handwheel hardware is specified at 50 pulses/revolution, A/B square-wave phases and 200 Hz maximum frequency response. The 46-group output section gives 20 mA maximum at 5 V ±5% and 30 mA maximum at 24 V ±5%. Match MPG supply, receiver voltage and output circuit before connecting a PLC/drive input; these are not auxiliary power-output ratings.

Cables, serial wiring and D-SUB

HS uses RS-422 TX/RX pairs or RS-485 D+/D− according to mode. HE uses Ethernet through its LAN connection. A similar-looking item under programming and HMC cables is not sufficient evidence of DOP-107H compatibility. Select communication accessories by electrical standard and protocol.

The 7H02 25-pin D-SUB table assigns pin 25 to +24 V and pin 13 to 0 V; pins 7/8 to emergency-stop NO, 9/10 to NC; and 22/23 to the three-position-switch NO contact. This scope is limited to the listed HE42xZM, HE46xZM and HE47xZD groups. Check the drawing’s connector orientation; mechanical fit does not establish equivalence.

The manufacturer advises against extending the integrated cable with arbitrary additional wires. Power, LAN/serial communication, MPG and safety contacts have separate functions within the cable. Include voltage drop, protective grounding, strain relief and crushing hazards when reviewing mounting and power connections.

DOPSoft 4, project conversion and DIAScreen

The archived DOPSoft 4 manual’s section 1.3 support table lists HE42, HE46, HE47, HS42 and HS46 targets and describes opening DOP-H projects on DOP-107H targets for conversion. Delta Türkiye’s April 2023 manufacturer list states that DOPSoft 2 → DOPSoft 4 conversion is not reversible. Preserve the original and convert a copy.

DOPSoft 4 maintenance ended on 23 October 2023. Delta recommends DIAScreen. DOPSoft 4 remains a historical project-maintenance reference; check exact target and version support through the official Delta download centre for a new installation. Screen Editor, DOPSoft 2, DOPSoft 4 and DIAScreen are different project generations.

After conversion, test physical-key addressing, MPG, PLC driver, screens, macros, alarms and recipes under controlled conditions. Opening a project does not validate cable pins, safety contacts or machine behaviour. USB Client 2.0 connects to the PC; it is not USB Host or the same transfer medium as SD/SDHC.

24 V supply and servicing

7H02 specifies 24 V DC ±15% — 20.4–27.6 V DC and 4.896 W panel consumption. A suitable SELV supply is required; this power figure excludes connected peripherals. Choose shared HMI power supplies for the complete load. Do not copy another DOP family’s supply tolerance.

The listed backup battery is CR2450, 3 V. The manufacturer directs users to its distributor/service when a battery warning appears; preserve the project and required retained data first. Items under HMI modules and accessories, Ethernet expansion, digital I/O expansion and remote I/O are not automatically compatible additions to the panel’s built-in Ethernet/serial hardware.

Editor’s note

Record the complete label, cable end and working project first. Keep HS/HE, 42/46 and ZM/ZD distinct. “107H” alone does not identify the correct replacement or cable.

Check emergency-stop contacts against the exact circuit. Two NC contacts and an NO+NC arrangement require separate verification. An on-screen indication does not prove the external contacts work; test with the machine in a safe state.

Inspect cable entry, bending points and connector locks. Intermittent communication or resets may come from a moving broken conductor or voltage drop. Avoid improvised cable extensions.

Test more than whether the handwheel turns. Verify A/B pulses, receiver voltage, the three-position switch and every physical key. A 21-key unit is not validated by a 15-key project mapping.

Check touchscreen corners, SD cover, USB and seals. The 750 g figure excludes the cable; assess both. Treat this as a handheld assembly rather than beginning with a fixed-panel cutout.

Keep the only working DOPSoft project safe during conversion. Back up source and recipes, then verify keys, MPG, alarms and communication-loss behaviour under controlled conditions. Follow manufacturer service instructions for a battery warning.

Related families and HMI documents

DOP-A, DOP-AE and DOP-AS are legacy Screen Editor families. DOP-B and DOP-W are fixed panels; HMC07 and HMC08 include motion-control functions. HMI communication alone is not motion control.

TP text panels, TP04P and TP70P have their own software/control structures. Select HMI starter kits by complete panel and cable configuration.

Use Delta HMI PDF files and Delta PLC and HMI manuals. Return to Delta HMI families or browse available used Delta products.

Manufacturer documents and external references

The DOP-107H 7H02 instruction — includes Turkish is printed 9 July 2021, 5014115102-7H02: PDF p.1 codes/pins, p.2 specifications and pp.3–4 Turkish. The earlier 7H00 sheet hosted by SIT Automation has 20191016 in its download filename but is printed 15 August 2019. The two editions have different scope.

The Delta Türkiye April 2023 product/price list gives four complete codes and conversion notes on PDF p.104. Prices are historical. The 30 December 2021 DOPSoft 4 manual lists targets/conversion on PDF p.14. These are third-party-hosted manufacturer documents.

Delta’s DOPSoft 4 maintenance-end advisory establishes software status; Delta’s DOP-H07 discontinuation entry establishes the older family’s replacement direction. Document/access dates are not universal hardware revisions or production-end dates.