Delta AS320P-B
Delta AS320P-B PLC CPU
The Delta AS320P-B is a PLC CPU in the Delta AS300 family. It runs on 24 V DC and has 8 digital inputs and 12 PNP transistor outputs, removable spring terminals and a 128k-step program capacity.
Digital I/O and pulse control
X0.0–X0.7 are 24 V DC inputs. Set the S/S common for the PNP or NPN wiring of the selected inductive sensor. The Y0.0–Y0.11 PNP outputs source current to the load. Resistive-load ratings are 5–30 V DC, 100 mA per output and 1.2 A per common.
Delta specifies four 200 kHz high-speed counters for signals such as encoder pulses and pulse outputs for up to six axes at 200 kHz for compatible pulse-input servo applications. Check the axis and input assignments in the project hardware settings.
Programming and expansion
Use ISPSoft for the project and select the connection in COMMGR. Connect the PC with a data-capable Mini USB cable or an RJ45 Ethernet cable. Section A.5 of the manual covers the Windows 11 USB driver. The CPU has two RS-485 ports and one Ethernet port. It supports serial Modbus, Modbus TCP and EtherNet/IP. CANopen requires a compatible function card.
The system supports up to 32 AS expansion modules and 1,024 physical I/O points in total. Check module-type limits and the power budget when adding digital or analog modules.
Related models and differences
The AS320T-B has the same I/O count with NPN outputs. The AS332P-A uses PNP outputs, 16 inputs, 16 outputs and MIL connectors. The AS324MT-A offers differential pulse interfaces. The AS300N-A is a CPU configured with external I/O modules.
Editor’s Note
Check for the full AS320P-B code and make sure the input and output terminal blocks are present.
Photograph the terminal and C0 markings before moving a panel so you can reconnect it correctly.
If an input LED stays off, start with the sensor type and the S/S common.
If an output LED lights but the load stays off, measure the C0 supply and check the load return.
Back up the project and network settings before swapping the CPU. Keep machine movement disabled during the first I/O test.