Danfoss VLT 2800 user manual

Hello,

Below you can find user manuals and catalog information of Danfoss VFD VLT 2800 speed controllers.
It is specified in the file names in English.

If you are going to look at the fault codes for the VLT2800 driver;
+ Chapter 1 error codes (Alarms and solutions)
 2nd part fault codes (Fault codes and solutions)
You can find the solutions on their pages.

+ Danfoss Vfd VLT2800 detail user manual  (pdf)

+ Danfoss Vfd VLT2800 Quick manual  (pdf)

+ Danfoss Vfd VLT2800 building manual  (pdf)

+ Danfoss Vfd VLT2800 parameter list  (pdf)

+ Danfoss Vfd VLT2800 modbus communication (pdf)

 

001 Language [0]=English, [1]=German, [2]=French, [0]=English [3]=Danish, [4]=Spanish, [5]=Italian
002 Local/remote [0]=Remote operation, [0]=Remote operation [1]=Local operation operation
003 Local reference 0-fMAX / RefMIN -Ref MAX / -RefMAX - +RefMAX 000,000.000
004 Active Setup [0]=Factory Setup, [1]=Setup 1, [1]=Setup 1 [2]=Setup 2, [3]=Setup 3, [4]=Setup 4, [5]=Multi Setup
005 Programming [0]=Factory Setup, [1]=Setup 1, [5]=Active Setup Setup [2]=Setup 2, [3]=Setup 3, [4]=Setup 4, [5]=Active

Setup
006 Setup See manual [0]=No copying copying
007 LCP copy [0]=No copying, [1]=Upload all [0]=No copying parameters, [2]=Download all parameters, [3]=Download powerindependent parameters
008 Display scaling of 0.01 - 100.00 1.00 output frequency
009 Large display See manual [4]=Frequency readout [Hz]
010 Small display See manual [1]=Reference readout 1.1 [%]
011 Small display See manual [6]=Motor readout 1.2 current [A]
012 Small display See manual [8]=Power [kW] readout 1.3
013 Local control [0]=Local not active, [4]=Remote [1]=Local control and open loop, operated control [2]=Remote operated control and open as par. 100 loop, [3]=Local control as par. 100,
[4]=Remote operated control as par. 100
014 Local stop/Reset [0]=Not active, [1]=Active [1]=Active
015 Local jog [0]=Not active, [1]=Active [0]=Not active
016 Local reversing [0]=Not active, [1]=Active [0]=Not active
017 Local reset [0]=Not active, [1]=Active [1]=Active of trip
018 Lock for [0]=Not locked, [1]=Locked [0]=Not locked data change
019 Operating mode [0]=Auto restart, use saved ref. [1]=Forced stop, at power-up, [1]=Forced stop, use saved ref. use saved ref. local operation [2]=Forced stop, set ref. to 0
020 Lock for Hand [0]=Not active, disable [1]=Active, enable mode [1]=Active, enable
024 User-defined [0]=Not active, [1]=Active [0]=Not active

Quick Menu
025 Quick Menu [Index 1-20] 000 Setup Value 0-999
100 Configuration [0]=Speed regulation, open loop [0]=Speed
[1]=Speed regulation, closed loop regulation,
[3]=Process regulation, closed loop open loop
101 Torque [1]=Constant torque [1]=Constant characteristic [2]=Variable torque, low torque
[3]=Variable torque, medium
[4]=Variable torque, high
[5]=Variable torque, low CT start
[6]=Variable torque, medium CT start
[7]=Variable torque, high CT start
[8]=Special motor characteristic
102 Motor power PM,N 0.37-11 kW Depends on unit
103 Motor 200-240 V/380-480 V Depends on unit voltage UM,N
104 Motor 24-1000 Hz 50 Hz frequency fM,N
105 Motor 0.01-IMAX Depends on current IM,N choice of motor
106 Rated 100-fM,N x 60 (max. 60000 rpm) Depends on motor speed choice of motor
107 Automatic [0]=Optimisation off [0]=Optimisation motor tuning [2]=Optimisation on off
108 Stator 0.000-X.XXXΩ Depends on resistance RS choice of motor
109 Stator 0.00-X.XX Ω Depends on reactance XS choice of motor
119 High start torque 0.0 - 0.5 sec. 0.0 sec.
120 Start delay 0.0-10.0 sec. 0.0 sec.
121 Start function [0]=DC hold during start delay time [2]=Coasting
[1]=DC brake during start delay time during start
[2]=Coasting during start delay time delay time
[3]=Start frequency/voltage clockwise
[4]=Start frequency/voltage in reference direction
122 Function at stop [0]=Coasting [0]=Coasting [1]=DC hold
123 Min. frequency 0.1 - 10.0 Hz 0.1 Hz for activating of function at stop
126 DC brake time 0-60 sec. 10 sec.
127 DC brake cut-in 0.0 (OFF) - par. 202. Output frequency OFF frequency high limit, fMAX
128 Motor thermal See manual [0]=No protection protection
130 Start frequency 0.0-10.0 Hz 0.0 Hz
131 Voltage at start 0.0 - 200.0 V 0.0 V


- Danfoss Vfd VLT2800 Fault codes

- Danfoss VFD Contact     

+ Danfoss VLT 2800 user manual 


+ Danfoss Main Page (2) >>

+ VFD Home page >>  


-

"* The user manuals, commissioning suggestions, error codes, and solution recommendations provided on this page are not binding. The information and documents above are open to and even in need of improvement. As the Otomasyon Mall Community, we gladly welcome your suggestions and contributions. If you have field experience and insights on ease of use, please do not hesitate to share them with us."  12.01.2013 