Gemo DZ307 (digital timer) timer  

- We have been selling Gemo products on our website since 2013.

    Input supply voltage 220v (24 volt supply must be specified with order)
    Input type ; 24v...12v dc contact or sensor
    Output type ; with relay output (must be specified in order for SSR)

>> When START input is ON, Out becomes ON after t.Set time. If START input is OFF, Out becomes OFF. If RESET input is ON, Out becomes OFF.

>> Out turns ON when START input is triggered (OFF > ON) or (ON > OFF), and turns OFF after t.SEt time. START input can trigger again when Out is ON. If RESET input is ON, Out becomes OFF.

>> Out becomes ON after t.SEt time after START input is triggered (OFF > ON). The START input does not trigger the timer again until it is reset with the RESET input. If RESET input is ON, Out becomes OFF.

>> If START input is ON, Out periodically turns ON for t.On time and then OFF for t.OFF time. If START input is OFF, Out becomes OFF. If RESET input is ON, Out becomes OFF.

>> Out turns ON when START input is triggered (OFF > ON), and turns OFF after t.SEt time. START can trigger again when Out is ON. If RESET input is ON, Out becomes OFF.

>> When START input is triggered (OFF > ON), Out periodically turns ON for t.On time and then OFF for t.OFF time. If RESET input is ON, Out becomes OFF.

>> Out turns ON when START input is triggered (OFF > ON), and turns OFF after t.SEt time. START cannot trigger again when Out is ON. If RESET input is ON, Out becomes OFF.

>> When START input is triggered (ON > OFF), Out becomes ON after tA time and OFF after tB time. A new trigger is not received from the START input before the tB time expires. If RESET input is ON, Out becomes OFF.

Out becomes ON after t.SEt time when the device is energized. The START input is not used. If RESET input is ON, Out becomes OFF.

>> If START input is ON, Out becomes ON and time counts up. When START input is OFF, counting time stops and the time value on the display remains constant. If the time value exceeds the t.SEt value, the display becomes RESET when the START input is OFF. If RESET input is ON, Out becomes OFF.

>> If START input is ON, Out is ON. Out becomes OFF after t.SEt time after START input is triggered (ON > OFF). If RESET input is ON, Out becomes OFF.

>> Out turns ON when START input is triggered (ON > OFF), and turns OFF after t.SEt time. If START input is ON, Out becomes OFF. If RESET input is ON, Out becomes OFF.

>> If START input is ON, time counts up. When START input is OFF, counting time stops and the time value on the display remains constant. Out is ON if the time value exceeds t.SEt. If the RESET input is ON, the Out becomes OFF and the display is reset.

Notes: 1. For Mode 1; t.On and t.OFF values ​​are at least 000.1 sec, 00.01 min. and 00.01 hours are accepted. On the other hand, you can browse time relay prices.

2. Time counts forward in Mode 6 and Mode 7, and time counts down in other modes. 3. For all output functions; Time counting stops (freezes) when GATE is ON.

 Size : 72x72mm
- Panel Section: 70x70mm
- Display : 2x4 Digit 7 Segment display
- Input : START / RESET / GATE input 3 x max. 32VDC (OFF:0..2VDC, ON:7..32VDC)
- GATE Input : When the GATE is ON, time counting stops.
- Output : Out Relay (NA-O-NC), 250VAC, 2A, Resistive load SSR Out; open collector (NPN output), 30V,100mA max.
- Time Selection: 99:59 hours / 99:59 minutes / 599.9 seconds
- Sensitivity : 1 min. / 1 sec. / 0.1 sec.
- Accuracy : ± 0.5% (of Full Scale)
- Output Function: 13 types selectable
- Sensor Supply Exit. : 12VDC, 50mA max. (unregulated)
- Supply Voltage: 100..240VAC, 50-60Hz or 24Vac/dc (optional)
- Power Consumption: < 6VA
- Relative Humidity: 80% up to 30oC, then linearly decreasing to 50% at 50oC (non-condensing)
- Operating altitude : < 2000 m

- Magnetic compatibility: It can work on the same board with ac drive systems.

- Gemo DZ307 user manual -

+ Gemo Price list

+ Gemo Contact

++ Gemo electronic main page

+ Control devices main page  

---------

Attention please !! All assembly of Gemo electronic drives should ONLY be performed by qualified technical personnel. Installation must always be carried out in accordance with applicable (2006/42 / EC) relevant ministry laws or regulations. Otomasyon AVM does not accept any responsibility for installations and individuals that violate local laws and / or other regulations (for overseas sales). Instructions given by GEMO no, the device is under warranty coverage. This detailed information is detailed in detail. For detailed information, you can contact adress gemo@otomasyonavm.com.

Write a review

Note: HTML is not translated!
    Bad           Good

Gemo DZ307

  • 370.00USD

  • Ex Tax: 370.00USD