ATEX Standards

ATEX Standards

Choosing suitable equipment for explosive atmospheres

ATEX derives from the French expression Atmosphères explosibles. It is not a single technical standard or a certificate issued in the same way for every product. It is a regulatory framework covering equipment, protective systems and workplace precautions associated with explosive atmospheres. The hazard is not confined to oil and gas facilities; plants handling combustible flour, feed or wood dust also require assessment.

2014/34/EU sets essential health and safety requirements and conformity assessment procedures for products within its scope. 1999/92/EC concerns workplace explosion-risk assessment, hazardous-area classification and worker protection. Product conformity and installation safety are separate responsibilities. Türkiye also has corresponding product legislation under 2014/34/AB; describing ATEX as a standard used only in EU countries is inaccurate.

Editor's note: Not all Ex equipment provides protection by containing an explosion. Some methods prevent flame transmission, others reduce sparking or heating, and others limit electrical energy. Instead of relying on “ATEX approved,” check the atmosphere, the zone, the protection method and the conditions of use for which the equipment is suitable.

How do Ex, ATEX and IECEx differ?

Ex refers to explosion-protection methods and associated markings. Technical requirements are commonly specified in standards such as the IEC 60079 series. ATEX is market legislation; for equipment within its scope, CE marking, the specific explosion-protection mark and required additional information must be considered together. The letters “Ex” alone do not establish document authenticity or suitability for every explosive atmosphere.

IECEx is an international certification system based on IEC standards. ATEX and IECEx may share technical foundations, but they are different legal and assessment frameworks. An IECEx certificate does not automatically complete the conformity procedures required by the destination country.

How are gas and dust zones classified?

A zone describes the frequency and duration of an explosive atmosphere, rather than equipment quality. Gas, vapour and mist use zones 0, 1 and 2; airborne combustible dust clouds use zones 20, 21 and 22. In particular, Zone 1 means that an explosive atmosphere is expected to arise occasionally during normal operation; it is distinct from Zone 2.

Gas / vapour / mist Combustible dust cloud Atmosphere occurrence Typical minimum category
Zone 0 Zone 20 Present for extended periods, repeatedly or without interruption. 1G / 1D
Zone 1 Zone 21 Expected to arise occasionally during ordinary operation. 2G / 2D
Zone 2 Zone 22 Not expected in ordinary operation; if present, remains briefly. 3G / 3D

The category mapping concerns ATEX Group II; G denotes gas and D denotes dust. Provided all other requirements are met, category 1 equipment can also serve lower-risk zones, and category 2 equipment can serve Zone 2 or 22. Mining uses Group I and the M1/M2 categories. Zone type and extent depend on material properties, release sources and ventilation. There is no universal distance or hourly threshold for every installation.

Protection methods use different principles

Ex d flameproof enclosures are designed to withstand an internal explosion and prevent ignition of the surrounding atmosphere. Ex e increased safety uses design measures to reduce hazardous sparking and temperatures. Ex i intrinsic safety limits the electrical and thermal energy available for ignition.

Ex m encapsulation protects potential ignition sources within suitable material. Ex p pressurization uses protective gas to prevent entry of a hazardous atmosphere. Ex t provides dust protection through control of dust ingress and surface temperature. The protection letter alone does not establish zone suitability. The protection level and certificate conditions must also be checked.

A high IP protection rating does not turn an ordinary enclosure into Ex equipment. An IP65 enclosure alone does not provide flameproof protection or intrinsic safety for a gas atmosphere.

Read the marking alongside the documentation

An illustrative gas-equipment marking is II 2G Ex db IIC T4 Gb. II identifies the non-mining equipment group, 2G category 2 for gas, db the flameproof protection level, IIC the gas subgroup and Gb the equipment protection level. The T4 temperature class specifies a maximum permitted surface temperature of 135 °C under the stated conditions; it does not mean that the ambient or process temperature may be 135 °C. A gas marking does not automatically establish dust suitability.

An X suffix on a certificate number draws attention to specific conditions of use. A U suffix identifies an Ex component requiring further assessment within the final equipment, rather than a standalone, ready-to-use device. The model, ambient-temperature range, cable entries and certificate schedules must match the product.

Not every ATEX product follows the same third-party certification route. Category 3 equipment has a manufacturer internal-production-control route; the role of a notified body varies for higher categories and different product types. This distinction does not reduce the importance of technical documentation, the declaration of conformity and operating instructions.

Maintaining protection in service

A device selected for Zone 1 can lose its suitability through an incorrect cable gland, a modified enclosure or wiring contrary to its instructions. Dust deposits can impair cooling and introduce hot-surface hazards. Equipment selection therefore needs correct installation, earthing and bonding, cleaning, inspection and maintenance. Buying certified equipment does not replace the workplace explosion-risk assessment or the explosion protection document.