What is SSCNET?

Mitsubishi Electric SSCNET servo communication network

SSCNET — Servo System Controller NETwork is Mitsubishi Electric's dedicated high-speed communication network for servo and motion-control systems. It connects motion controllers or compatible PLC motion modules with servo amplifiers so that position commands, speed information, operating status, alarms and other servo data can be exchanged in a synchronized manner.

In simple terms: SSCNET allows several Mitsubishi servo axes to work together through a dedicated digital network instead of relying on separate pulse-command wiring for every axis. This is particularly useful when several servo drives and motors must move with accurate timing and synchronization.

Who developed SSCNET?

SSCNET is a Mitsubishi Electric servo-system technology. The expansion “Sanyo Serial Communication Network” found in some older descriptions is incorrect. Mitsubishi Electric documentation explicitly defines SSCNET as Servo System Controller NETwork.

The network forms part of Mitsubishi's wider factory automation and motion-control ecosystem. It is primarily intended to connect Mitsubishi motion controllers, Simple Motion modules and compatible MELSERVO servo amplifiers rather than to operate as a general-purpose plant Ethernet network.

What is SSCNET used for?

Traditional servo systems can receive position commands through pulse trains or analog references. These methods can work well for individual axes, but wiring and synchronization become increasingly complicated as the number of coordinated servo axes grows.

SSCNET creates a digital communication link between the motion controller and the servo amplifiers. The controller can issue motion commands while receiving actual position, operating status, alarm and servo-monitoring information from the connected axes.

This makes the network particularly useful for applications involving electronic gearing, electronic cam functions, synchronized feeding, registration, flying-cut applications, packaging and other multi-axis motion-control and robotic systems.

What is SSCNET III/H?

SSCNET III/H is a high-speed generation of Mitsubishi's optical servo-system network. It uses dedicated fiber-optic communication between the controller and compatible servo amplifiers.

Mitsubishi Electric specifies SSCNET III/H communication at 150 Mbit/s full duplex. In supported systems, communication cycles can be as short as 0.222 ms. These characteristics allow servo information to be updated rapidly while maintaining accurate synchronization between axes.

The practical number of axes depends on the motion controller and system architecture. Some Mitsubishi iQ-R motion systems support up to 32 axes over SSCNET III/H, but this should not be interpreted as one universal axis limit for every SSCNET controller ever produced.

What is the difference between SSCNET III and SSCNET III/H?

SSCNET III is an earlier optical version of the servo network. Mitsubishi documentation lists a communication rate of approximately 50 Mbit/s for SSCNET III, while SSCNET III/H increases this to 150 Mbit/s full duplex.

SSCNET III/H also improves communication-cycle performance and synchronization for demanding motion systems. Some SSCNET III/H controllers can operate with compatible SSCNET III servo amplifiers in the same system, although available features and performance may be limited by the older equipment.

For this reason, an MR-J3, MR-J4 or another Mitsubishi servo generation should not be connected simply because the optical connector appears compatible. The controller, servo amplifier and required operating mode must be checked against Mitsubishi's compatibility information.

Why does SSCNET use fiber-optic cable?

The optical physical layer used by SSCNET III and SSCNET III/H provides strong immunity to electromagnetic interference. Fiber does not conduct electrical noise from motor power cables, contactors or high-frequency switching equipment into the servo communication path.

This is especially valuable inside machines containing several servo amplifiers, motors and power electronics. High-power drive wiring can create an electrically harsh environment in which conventional copper communication lines require careful EMC design.

Fiber-optic communication is resistant to electrical interference, but the cable still requires correct mechanical installation. Excessive bending, crushing, contaminated connectors or physical damage can interrupt SSCNET communication.

How is SSCNET wired?

SSCNET III/H controllers and servo amplifiers are connected using Mitsubishi-compatible optical SSCNET cables. The network allows several axes to share one structured digital servo network rather than requiring separate position-command and monitoring wiring for every axis.

This can considerably reduce wiring in machines containing many servos. It also centralizes control and diagnostics because large amounts of servo information can be exchanged between the controller and multiple amplifiers through the same network architecture.

Cable distance depends on the controller, servo amplifier and optical cable type. Mitsubishi documents SSCNET III/H systems capable of up to 100 m between stations and 3200 m per system in supported 32-axis configurations. These values should be treated as capabilities of specified systems rather than as guaranteed distances for every older SSCNET installation.

What information is transmitted over SSCNET?

SSCNET is much more than a digital run/stop connection. The controller and servo amplifiers can exchange motion commands, actual servo information, operating status, parameters and diagnostic data through the network.

Mitsubishi engineering tools such as MR Configurator2 can also work through compatible motion controllers or Simple Motion modules to monitor and configure multiple servo amplifiers. This can reduce the need to connect a separate engineering cable to every amplifier during commissioning and maintenance.

This centralized approach is particularly useful in larger PLC and motion-control systems where several servo axes must be commissioned, monitored and diagnosed together.

OtomasyonAVM also contains actual Mitsubishi positioning hardware using the network. For example, the Mitsubishi QD75MH2 is a two-axis positioning module using SSCNET III, while the QD75MH4 provides four-axis SSCNET III positioning control.

Why is SSCNET useful for synchronized motion?

In a multi-axis machine, commanding two servo motors to run at approximately the same speed is often not enough. The axes may need to maintain an exact angular or linear relationship throughout the complete machine cycle.

Printing cylinders, packaging film, rotary cutters, winding systems and electronic-cam applications are typical examples. Communication timing between the controller and the drives therefore becomes part of the motion-control performance.

SSCNET III/H provides synchronized communication for this type of application. Its primary purpose is therefore very different from the function of an HMI or a plant-level SCADA system. An HMI displays production information; SSCNET operates inside the high-speed servo-control layer of the machine.

Is SSCNET an Ethernet network?

No. SSCNET III/H is not a general-purpose Ethernet or TCP/IP network. It is Mitsubishi Electric's dedicated optical communication system for servo controllers and compatible servo amplifiers.

It should therefore not be treated as simply another version of PROFINET, EtherNet/IP or EtherCAT. These technologies differ in physical layer, device model, network architecture, interoperability and intended use.

Are SSCNET and CC-Link the same?

No. CC-Link is a broader industrial communication family used with PLCs, I/O, drives, sensors and many other automation devices. Although Mitsubishi Electric has played an important role in CC-Link technology, CC-Link is not the same network as SSCNET.

SSCNET is focused specifically on communication between servo system controllers and servo amplifiers for high-performance motion control. A Mitsubishi machine may therefore use SSCNET for its servo axes while using CC-Link or another network for general machine I/O and other automation devices.

Modern Mitsubishi systems may also use CC-Link IE or CC-Link IE TSN for broader machine communication and motion applications. The presence of these newer network options does not change the function of existing SSCNET III/H installations.

What is the difference between SSCNET and EtherCAT?

SSCNET and EtherCAT can both appear in high-performance servo and motion-control applications, but they are fundamentally different technologies. SSCNET is a proprietary Mitsubishi Electric servo-system network. EtherCAT is an industrial Ethernet technology supported by equipment from many different automation manufacturers.

Protocol selection should therefore not be reduced to a comparison of nominal communication speeds. The motion controller, servo amplifier family, required synchronization functions, axis count, engineering software, machine architecture and maintenance strategy are all important.

Which Mitsubishi systems use SSCNET?

Different generations of Mitsubishi servo and positioning systems have used SSCNET, SSCNET III and SSCNET III/H. MR-J3 and MR-J4 servo families and several MELSEC-Q and iQ-R motion products are commonly associated with the later optical SSCNET generations.

For example, the FX3U-20SSC-H is an SSCNET III positioning module for Mitsubishi FX3U PLC systems. Mitsubishi Q-series modules such as QD75MH2 and QD75MH4 are other examples of installed SSCNET III motion hardware.

Mitsubishi's current motion-controller portfolio continues to include SSCNET III/H alongside newer networking technologies. When repairing or modernizing a machine, the exact controller and servo-amplifier model should therefore be identified before choosing replacement hardware or communication cables.

The wider Mitsubishi PLC and Mitsubishi programming software sections can also be useful when identifying older controllers and engineering environments found around these motion systems.

Where is SSCNET used?

SSCNET is most useful in machines requiring coordinated multi-axis motion. Applications include packaging equipment, printing machines, food-processing machinery, winding systems, assembly machines, material-handling equipment and high-precision positioning systems.

A Mitsubishi PLC or motion controller calculates the required movement and transfers servo commands over SSCNET to the amplifiers. The servo amplifiers control the motors and return operating information to the controller through the same network.

On the operator side, a Mitsubishi GOT HMI or another compatible operator panel may display machine status, recipes and servo alarms. The HMI interface and the SSCNET motion network perform different jobs even though both belong to the same machine-control system.

Why does an SSCNET network fail to communicate?

The first step is to confirm that the controller and servo amplifiers support compatible SSCNET generations. SSCNET III and SSCNET III/H equipment can be mixed in certain supported configurations, but this does not mean that every historical SSCNET device can be connected to every newer controller.

Next inspect the optical cables, connectors and connection sequence between amplifiers. Excessive cable bending, physical damage, incorrect port connections or contaminated optical interfaces can interrupt communication even when the servo amplifiers themselves are healthy.

If the physical network appears correct, check the motion-controller configuration, axis assignment and servo alarms. A machine that reports an SSCNET-related fault may actually have a compatibility, parameter or servo-amplifier problem rather than a failed fiber cable.

Practical SSCNET troubleshooting checklist

1. Do the controller and servo amplifiers support compatible SSCNET versions?

2. Is the correct Mitsubishi-compatible optical SSCNET cable installed?

3. Are the fiber cables connected to the correct input/output ports and in the required axis order?

4. Are any fiber cables crushed, sharply bent or mechanically damaged?

5. Do the axis and network parameters in the motion controller match the actual servo system?

6. Do any servo amplifiers report communication or servo alarms?

7. If SSCNET III equipment is being used in an SSCNET III/H system, have the compatibility limitations been checked?

8. Have the actual diagnostic messages in the Mitsubishi motion-engineering software been reviewed before replacing hardware?

Is this the same SSCNet used in artificial intelligence?

No. The abbreviation “SSCNet” has also been used in computer-vision research for Semantic Scene Completion Network, a deep-learning model concerned with semantic 3D scene completion. It has no technical relationship with Mitsubishi Electric's Servo System Controller NETwork. On this page, SSCNET refers only to the industrial servo and motion-control network.

Related Industrial Communication Guides

Industrial Communication · CC-Link · EtherCAT

Related Mitsubishi and Motion-Control Pages

Mitsubishi Electric · Servo Systems · PLCs · Mitsubishi HMI · Industrial Robotics