IC697BEM731

The Bus Controller Module (IC697BEM734/731) is a key component in the Series 90-70 Programmable Controller line. This module allows the PLC to interface with an IC66 (IC660 or IC661) I/O network*, providing robust I/O diagnostics, global communication capabilities, and redundancy support. Here is a summary of its primary features and functions:

Bus Controller Module - IC697BEM731

    Supports 30 drops per channel.
    IC66* (IC660 or IC661) I/O diagnostics.
    Redundant blocks, cables, and CPUs supported.
    Global communications.
    Handheld monitor port.
    IC66* LAN communications.
    Soft configuration via the CPU.
    Enhanced operation by IC697 PLC Alarm Processor function.

Functions:

The IC66* Bus Controller (GBC/NBC) is a single-channel controller that occupies one slot in the IC66* PLC system. Configuration is done using MS-DOS or Windows-based programming software. IC66* Input/Output blocks are scanned asynchronously by the controller, and I/O data is transferred to the CPU once per scan over the backplane of the IC697 PLC rack.

The controller also supports directed communications initiated by a PLC CPU Communication Service Request and can be configured for global communications.

Faults reported by the controller are handled by the PLC Alarm Processor, which timestamps and queues faults in a table. In peer-to-peer communication setups, the Bus Controller can serve as a communication node linking other devices (Bus Controllers, PCIMs, and IC66* devices) via the IC66* bus.

Installation:

    Refer to the appropriate PLC Installation Manual before attempting installation.
    Ensure that the rack power is off.
    Install the module in the rack.
    Turn on the power.

When powered up, the top LED should blink for about 5 seconds. After successful diagnostics, the top LED stays on. The middle LED lights up when a valid configuration is received from the CPU, and the IC66* I/O bus operation is verified. The bottom LED remains off under all conditions.

Bus Controller Operation:

The IC66* I/O serial bus transmits data by passing a "token" among the devices on the bus. During the bus scan, the Bus Controller:

    Receives all inputs from the I/O blocks.
    Collects any faults and sets diagnostic status references for the PLC CPU to access once per scan.
    Updates all outputs on the I/O blocks.
    Executes commands received from the CPU, such as Clear Circuit Fault.

Communications Window:

The Bus Controller communicates with the CPU via the communications window using the following commands:

    Pulse Test Outputs.
    Read Configuration.
    Write Configuration.
    Read Diagnostics.
    Clear Circuit Fault.
    Clear All Circuit Faults.
    Assign Monitor.
    Enable/Disable Outputs Global.
    Enable/Disable Data.
    Switch BSM.
    Read Device.
    Write Device.
    Dequeue Datagram.
    Send Datagram.
    Request Datagram Reply.

Handheld Monitor Port (1PL):

Port 1PL is for connecting a handheld monitor to the Bus Controller.

IC66* Bus Field Terminal Connections (3PL):

Connector 3PL provides the connection points for the IC66* bus. The serial bus must be terminated at both ends using the appropriate impedance resistors, which are included with the module.

Configuration:

Upon powering up, the Bus Controller assumes no default baud rate or serial bus address. These settings are configured through MS-DOS or Windows programming software, which defaults to 153.6K baud standard and serial bus address 31. The configured baud rate and serial bus address are transferred from the CPU during power-up or system initialization.

Setting the Baud Rate:

The default baud rate is 153.6 Kbaud (standard), which supports an IC66* bus length of up to 2000 feet. For longer distances, the baud rate can be adjusted accordingly to support up to 7500 feet. All devices on the bus must be configured to the same baud rate for proper operation.

Setting the Serial Bus Address:

The default serial bus address is 31, which can be modified using the MS-DOS or Windows software configuration function.

Dual Serial Busses with a BSM:

In applications requiring dual serial busses for backup communication paths, Bus Switching Modules (BSMs) can connect stubs of IC66* I/O blocks to two separate serial busses, each with its own Bus Controller or PCIM module.

Monitoring Bus Status:

Bus status can be monitored by connecting a handheld monitor to PL1 and accessing the Bus Status screen.

>> GE Fanuc IC697BEM731 User manual (pdf)

++ Other 90-30 PLC modules

----------

+ Ge-Fanuc 2 Homepage

+ Ge-Fanuc Contact (for Automation Mall)

+ About Ge-Fanuc

Reminder: GE Fanuc IC697BEM731 and other Ge-Fanuc modules are available for sale at Otomasyon Mall. Please note that some of the devices are used products, so take this into consideration when purchasing. However, once products are out of stock, new ones will not be restocked. The information above is based on general knowledge and does not guarantee accuracy. For more detailed and precise information, it is recommended to refer to the relevant device’s user manual. 06.03.2013 

"Please note: The user manuals, commissioning suggestions, error codes, and solution recommendations provided on this page are not binding. The information and documents above are open to and even in need of improvement. As the Otomasyon Mall Community, we gladly welcome your suggestions and contributions. If you have field experience and insights on ease of use, please do not hesitate to share them with us."