IC697BEM711

Bus Receiver Module (IC697BEM711)

The IC697BEM711 Bus Receiver Module (BRM) allows for the expansion from the main rack to up to seven additional IC697 PLC racks with a total interconnecting cable length of up to 50 feet (15 meters).

    High-Speed Parallel Bus Expansion Interface: Enables fast data communication between the main CPU and expansion racks.
    Supports up to Seven Expansion Racks: Allows up to 7 expansion racks to be connected to the main CPU rack.
    Hold Last State Support: Keeps output modules in their last state in case of communication loss with the CPU.
    System Fault Isolation: Allows isolation and repair of a faulty module within a rack.
    Three LED Indicators: Provide information on module status, bus termination, and expansion port activity.
    Easy Software Configuration: No DIP switches are needed, and the module is configured via software.

Functions:

    The Bus Receiver Module expands the main rack's capacity by enabling connection to up to seven additional racks.
    Hold Last State ensures that, in the event of a communication loss with the CPU, the output modules remain in their last known state.
    It provides fault isolation, allowing for easy identification and repair of faulty modules within the expansion rack.

Installation:

    Ensure the power to the rack is off before installation.
    Insert the module into slot 1 of the rack.
    Set the rack ID using BERG jumpers (as shown in Figure 1).
    Power up the system.

Note: Each Bus Receiver Module comes with a terminator plug (IC697ACC702), which is required only for the last Bus Receiver Module in the expansion chain.

LED Status Indicators:

    MODULE OK (Top LED): Turns ON when power is applied, the rack is configured, no fatal faults are present, communication with the CPU is established, and there is at least one other module in the rack.
    TERMINATION (Middle LED): Indicates the presence of the terminator plug; ON when the plug is present.
    BUS ACTIVE (Bottom LED): Turns ON when the CPU is in run mode and has communicated with the rack within the last 500 milliseconds. If this LED is off, the output modules switch to their configured fault state.

Wiring and Expansion Rack Connection:

The Bus Receiver Module is connected to a Bus Transmitter Module (BTM) in the CPU rack using IC600WDxxxA cables. Additional expansion racks are daisy-chained by connecting BRMs.
Removing a Module:

To remove the module:

    Firmly grasp the top and bottom of the board cover with your thumbs on the front and your fingers on the plastic clips at the back.
    Squeeze the rack clips to disengage the module from the rack rail and pull it out.
    Slide the module out along the card guide.

Technical Specifications:
Parameter    IC697BEM711
Current Required from 5V Bus    0.8 Amps
Maximum Cable Length    50 feet (15 meters)
Effective Data Rate    500 Kbyte/sec
Electrical Isolation    Non-isolated differential communication


Ordering Information:

    IC697BEM711: Bus Receiver Module.
    IC697ACC702: Terminator Plug.
    IC600WDxxxA: I/O Cables (various lengths available):
        5 ft (1.5 m),
        10 ft (3 m),
        25 ft (7.5 m),
        50 ft (15 m).

The Bus Receiver Module expands the capacity of the IC697 PLC system by allowing for the connection of additional expansion racks, providing fast and reliable data communication between the main CPU and these racks.



>> GE Fanuc IC697BEM711 User manual (pdf)

++ Other 90-30 PLC modules

----------

+ Ge-Fanuc 2 Homepage

+ Ge-Fanuc Contact (for Automation Mall)

+ About Ge-Fanuc

Reminder: GE Fanuc IC697BEM711 and other Ge-Fanuc modules are available for sale at Otomasyon Mall. Please note that some of the devices are used products, so take this into consideration when purchasing. However, once products are out of stock, new ones will not be restocked. The information above is based on general knowledge and does not guarantee accuracy. For more detailed and precise information, it is recommended to refer to the relevant device’s user manual. 06.03.2013 

"Please note: The user manuals, commissioning suggestions, error codes, and solution recommendations provided on this page are not binding. The information and documents above are open to and even in need of improvement. As the Otomasyon Mall Community, we gladly welcome your suggestions and contributions. If you have field experience and insights on ease of use, please do not hesitate to share them with us."