IC693CBL341
The IC693CBL341 PTM Interface Cable is a 39-inch (1 meter) long cable that connects the PTMPM Series 90-30 PLC module to the PTMIM DIN-rail mounted interface module. This cable is part of the IC693PTM101 assembly, which includes the PTMPM module, PTMIM interface module, and IC693CBL341 cable. The cable can also be ordered separately as an individual item.
PTM Product Ordering Information
The Processing Module and its Interface Board are considered a matched set and are not sold separately. However, the two PTM cables (IC693CBL340 and IC693CBL341) may be ordered separately.
Operating Modes
The PTM operates in one of the two following modes, which can be selected via a %Q bit in the user’s PLC application program:
Power Monitor Mode:
In this mode, the PTM samples AC voltage and current and calculates the RMS values of these waveforms. Several sub-modes are available and are selected via %Q bits in the PLC ladder logic program:
Single Mode:
Three single phases
One 3-wire single phase (120/240V)
3-Phase Mode:
In this sub-mode, complex power, energy consumption, and power factor are calculated. The options include:
Wye
Delta
Synchro Monitor Mode:
In this mode, the PTM samples three AC voltages produced by a generator and one voltage from the power grid. The module provides information on the voltages, frequencies, and relative phases.
Processing Module
The PLC CPU controls the PTM Processing Module by sending it several %Q bits and %AQ words during each PLC scan. These bits and words represent commands such as Enable/Disable, Power/Synchro Mode, Display Mode, and Gain values. In return, the Processing Module sends back information to the PLC CPU using %I bits and %AI words in each scan, which include data on voltage, current, power, and phase values, as well as fault status.
Interface Board
The PTM Interface Board features one 3-phase voltage input, one 3-phase current input, one 1-phase neutral current input, and an additional 1-phase voltage input. It has 8 separate input terminals for these voltage and current inputs. The terminal block accommodates 10 AWG wire, which is commonly used in power utility applications. The Interface Board uses a DB-25 connector and is connected to the Processing Module using either the IC693CBL340 or IC693CBL341 shielded cables.
The Interface Board translates 0 to 5 A current transformer (CT) signals and 120V potential transformer (PT) signals into 0 to 1 VAC signals for the Processing Module. However, the Interface Board does not include CT shorting bars, so these must be provided separately by the user.
This cable and its associated modules play a crucial role in power monitoring and synchronization, ensuring the system operates efficiently with accurate data exchange and real-time monitoring capabilities. Proper configuration and connection are key to ensuring seamless functionality.