IC693CBL300

IC693CBL300 and Related I/O Bus Expansion Cables for Electricians

What Are These Cables? The IC693CBL300 and similar cables are used to connect the Serial Bus Transmitter Module (IC695LRE001) to Expansion Backplanes (IC694/693CHS392 or IC694/693CHS398). Essentially, they allow you to expand the system by linking multiple backplanes together, extending the reach of your I/O bus.

These cables feature a 100% continuous shield, meaning they are designed to block any external electrical noise from interfering with the system. The shield is connected to the metal shell of the connector, providing a solid grounding path to prevent noise from entering the system.

Types and Lengths of Cables:

    IC693CBL300: 1 meter (3 feet)
    IC693CBL301: 2 meters (6 feet)
    IC693CBL302: 15 meters (50 feet)
    There are also smaller and longer versions available, depending on your system's needs.

Some of these cables come with three connectors in a "wye" configuration, while others only have two connectors. This allows for daisy-chaining up to seven expansion backplanes.

Key Details:

    For the last backplane in the chain, you’ll need a terminator to ensure the signal stays clean. Without this, you could run into errors or erratic system behavior.
    You can connect a maximum of seven backplanes, and the total cable length should not exceed 50 feet (15 meters) to avoid signal loss or interference.

What’s Inside the Cable: The cables carry various signals such as:

    DIODT: I/O Serial Data (positive and negative)
    DIOCLK: I/O Serial Clock
    DRSEL: Remote Select Signal
    DRMRUN: Remote Run Signal

Each signal pair has a positive and negative wire, and they are connected pin-to-pin (e.g., pin 2 connects to pin 2, pin 3 to pin 3, etc.).

Simple Installation Tips:

    For the best noise immunity, the cable shielding needs to be continuous and securely connected at both ends.
    After assembling, it’s a good idea to test the cable for continuity using an ohmmeter. This ensures that the metallic shield is making proper contact with the connector at both ends.

In short, these cables are crucial for reliable system performance. If they’re not properly installed or shielded, you could face communication errors. But with careful assembly and testing, these issues can be easily avoided.

>> IC693CBL300 cables User manual (pdf)

++ Other 90-30 PLC modules

----------

+ Ge-Fanuc 2 Homepage

+ Ge-Fanuc Contact (for Automation Mall)

+ About Ge-Fanuc

Reminder: IC693CBL300 and other Ge-Fanuc modules are available for sale at Otomasyon Mall. Please note that some of the devices are used products, so take this into consideration when purchasing. However, once products are out of stock, new ones will not be restocked. The information above is based on general knowledge and does not guarantee accuracy. For more detailed and precise information, it is recommended to refer to the relevant device’s user manual. 06.03.2013 

"Please note: The user manuals, commissioning suggestions, error codes, and solution recommendations provided on this page are not binding. The information and documents above are open to and even in need of improvement. As the Otomasyon Mall Community, we gladly welcome your suggestions and contributions. If you have field experience and insights on ease of use, please do not hesitate to share them with us."