6EW1000-4AB

Siemens 6EW1000-4AB SIMATIC S5 NiCd Backup Battery Module

Siemens 6EW1000-4AB is a plug-in backup battery module with a NiCd accumulator for SIMATIC S5 systems. Siemens lists the complete order number as a spare part in its ST 53 catalogue. In suitable equipment, it supports the retention of electronics and data that require buffering when the main supply is interrupted.

For Siemens automation and SIMATIC S5 systems, select the battery together with the connected power supply and hardware version. The product appears in our SITOP power supply section; this placement does not make it a standalone cabinet supply or a UPS for the entire machine.

Battery construction and identification

This model uses a NiCd, or nickel-cadmium, rechargeable battery. When comparing battery types, consider chemistry, rechargeability, voltage, capacity and mechanical connections together. Verify the battery pack’s voltage and capacity against the actual module markings and applicable system documentation.

Voltage at a battery’s terminals does not prove that it has adequate backup capacity. Actual retention time depends on cell condition, charge level, temperature and the system’s buffering current. Historical system runtimes are not a guaranteed operating time for an aged battery.

Compatibility and power supply matching

The manufacturer’s spare-parts table lists 6EW1000-4AB alongside the 6EW1160-5, 6EV2032-3 and 6EW1110-5 power supply families. This family listing does not establish unconditional compatibility with every suffix or hardware version. Match the charging and backup connections to the equipment’s documentation.

Complete version checks are needed for Siemens 6EV / 6EW models such as 6EW1110-5AA, 6EW1110-5AB and 6EW1110-5AC. A part that fits mechanically may still be electrically unsuitable. Assess the connector arrangement, polarity and charging circuit together.

Differences from other battery chemistries

6EW1000-7AA is a separate battery order number. A lithium battery and a NiCd accumulator do not have the same charging requirements. A matching nominal voltage is insufficient to approve replacement. Do not connect a non-rechargeable battery to a charging circuit.

Likewise, a conversion to NiMH or lithium-ion cells cannot be selected by physical size alone. A change of chemistry requires verification of the charging method, protection and manufacturer approval. Use a documented, suitable battery pack for reliable service.

Measurements and capacity testing

Use a suitable multimeter to check polarity and open-circuit voltage first. This reading does not replace a capacity test. A pack that loses charge rapidly or whose voltage collapses under load requires assessment in a controlled test arrangement separate from the system.

During capacity testing, record load current, duration, cell temperature and voltage together. Obtain the discharge cutoff and charging conditions from the correct cell specifications. Do not connect an ammeter directly across the battery terminals; doing so can create a short circuit.

Contact resistance and oxidation can cause backup problems even with healthy cells. Inspect connectors, spring contacts and wiring. If a battery warning is present, assess the charging and monitoring circuitry as well as the battery pack.

Cell renewal and maintenance

If renewing the cells, use a suitable matched pack with the correct chemistry, capacity and charging characteristics. Do not assemble an arbitrary mixture of old and new cells. Do not charge a pack showing leakage, corrosion, swelling or unusual heating. Check whether damage has reached the connections or surrounding circuitry.

Before removing the battery, obtain a usable backup of the program and required data. Whether replacement requires power on or off is system-specific; do not apply a universal sequence. Removing both main power and battery support can remove the buffering supply. Follow the system’s maintenance instructions for replacement and subsequent checks.

Editor’s Note

Do not immediately stop the machine and pull this small module after identifying a battery problem. First establish that the program and required data can actually be backed up. Verifying the backup now is easier than searching for a missing program later.

Do not declare the battery healthy from a no-load voltage reading. An aged pack may look satisfactory on a meter and collapse under the real load. Ask for voltage and duration recorded under a controlled load, with the test conditions stated clearly.

A battery warning is not necessarily caused by the cells alone. A spring contact, socket, cable or charging circuit can also be responsible. Check the charging path and contacts before fitting a replacement pack, so the new battery does not soon develop the same problem.

Do not accept “the voltage matches” as the complete replacement check. Replacing NiCd with another chemistry also affects the charging circuit. Use the correct chemistry and connections; do not attempt to revive the pack with a short circuit or a high-current pulse.

For a used module, ask when its cells were renewed and how capacity was tested. A clean cover does not establish that the pack inside is new. Keep the renewal date, cell details and test result together for the next maintenance visit.

OtomasyonAVM Resources and PDFs

Use the 6EW1000-4AB model page and Siemens SITOP files to find the related resources.

+ Siemens SIMATIC S5-130 / S5-150 — ST 53, 1985, German, 144 pages. The exact 6EW1000-4AB code, NiCd backup-battery description and power supply families appear on printed page 9/9, PDF page 127. This catalogue is not a detailed charging or replacement procedure.

Related Topics

NiCd batteries + Battery types + Multimeter measurements + Siemens S5 system information

Used-equipment enquiries: Provide the complete model, quantity, working/faulty condition, cell-renewal information, clear nameplate photographs and price. Sales are invoiced; returns are not accepted for used equipment. Workshop testing can be arranged with an agreed test scope. To offer a unit for sale, send its details to otomasyonavm@gmail.com.

Browse Categories

Used Siemens equipment + SITOP power supplies and accessories + Siemens 6EV / 6EW models + About SIMATIC S5 + SITOP PDF archive

Siemens and External References

+ Siemens ST 53 / 1985 — externally archived manufacturer catalogue