Siemens 6EV2031-4FC00 – SIMATIC S5 220 V AC / 5 V DC 10 A Power Supply

Siemens 6EV2031-4FC00 is a legacy SIMATIC S5 power supply providing a 5 V DC / 10 A system output from a 220 V AC input. It supplies the control electronics’ low-voltage rail. The 10 A rating belongs to the 5 V output, not the mains input.

It appears in the Siemens SITOP power supply and 6EV / 6EW model sections on OtomasyonAVM. Preserve the final two digits in 6EV2031-4FC00 when ordering. The shorter 6EV2031-4FC reference is also listed as an S5-130A supply; verify the actual rack interface, hardware revision and backup arrangement separately.

Electrical ratings and order-number differences

The basic voltage ratings are 220 V AC input and 5 V DC output, with a nominal output current of 10 A. Calculated nominal output power is 5 × 10 = 50 W; this does not establish total input consumption. Do not apply another mains voltage or a DC input without checking the nameplate.

The Siemens ST 53 catalogue lists 6EV2031-4EC00 and 6EV2031-4FC01 as separate order numbers. Their tolerances, battery specifications and connections must not be assigned directly to 4FC00. Pay particular attention to the 00 versus 01 suffix.

Connections and checking the 5 V rail

Connect the mains side, electronic reference and protective grounding according to the machine drawings. Photograph wire numbers, connector orientation and links before removal. Do not borrow pin assignments from a neighbouring model without verified 4FC00 wiring documentation.

Use a suitable multimeter for DC voltage measurements at identified output points. Compare the supply voltage with the voltage reaching the control card. Investigate connectors, wiring and backplane contacts when a voltage drop is present; an unloaded reading alone is insufficient.

At 5 A, a contact resistance of 20 mΩ produces a 0.1 V loss under Ohm’s law. This illustrates the importance of connection quality on a low-voltage rail; it is not a mandatory test current. Do not compensate for poor contacts by raising the output setting.

Fault isolation and load testing

If the CPU fails to start or stops intermittently, observe input, output and voltage fluctuations together. Exclude a system card drawing excessive current or causing a short circuit before condemning the supply alone. Apply controlled load gradually using suitable connections and the unit’s own operating limits.

If a fuse opens, do not increase its rating or repeatedly energize the unit. First investigate why it failed. After disconnecting power and verifying that stored voltage has been safely removed, inspect power components, diodes, solder joints and capacitors.

Observe voltage regulation during cold start, controlled loading and warm operation. For ripple measurements, use differential or isolated equipment suitable for the circuit. Never connect an earth-referenced oscilloscope ground clip to an arbitrary mains-side node.

Used-unit selection and backup arrangements

When selecting a used power supply, request clear nameplate, front-panel and connector photographs plus repair history. A useful test record identifies load current, output voltage, duration and thermal behaviour. Back up programs and machine data before removal; establish the type and purpose of any battery. Do not select battery chemistry or capacity solely by comparison with another model.

Editor’s Note

Keep the input and output clearly separated. This model converts 220 V AC to a 5 V system supply. Check the nameplate and machine drawings rather than following connections used for a previous 24 V input unit.

Small losses on a 5 V rail can cause major problems. Measure at the CPU as well as the supply. Repair hot or loose contacts before considering an output adjustment.

Use a suitable measurement arrangement on the mains side. Allow for high voltage and stored energy. Disconnecting power does not establish that the capacitors have discharged.

Record cold and warm behaviour separately. For delayed starting or thermal shutdown, measure and inspect solder joints, power connections and capacitors. Confirm the fault before replacing components indiscriminately.

Do not treat 00 and 01 as the same version. Supply the complete code, nameplate photographs and connector views. Similar appearance does not prove identical battery, monitoring or rack arrangements.

Complete the check under load. In a suitable system and under safe conditions, verify starting and warm operation, recording current and duration. These are general service recommendations, not verified recurring faults specific to this model.

Documents and PDF Resources

Browse our Siemens SITOP files document index and the Siemens 6EV / 6EW model pages.

Siemens SIMATIC S5-130 / S5-150 – ST 53 Catalogue. German, 1985 edition with May 1985 changes, 144 pages, 15.31 MiB. PDF page 90 / printed 8/4 and PDF page 127 / printed 9/9 cover the related supply family. These tables concern 4EC00 and 4FC01; this is not an exact 4FC00 datasheet.

Related Topics

6EV3053-0DC + 6EV3053-0EC + 6EW1110-5AC + 6EW1110-5AE. These are different system supplies; the links are not direct replacement recommendations.

Used equipment enquiries: Provide the brand, full model, quantity, working/faulty condition, nameplate photographs and price. Sales require an invoice; returns are not accepted for used products. Workshop testing can be arranged with an agreed scope. To offer equipment for sale, send details to otomasyonavm@gmail.com.

Browse Siemens Power Supplies

Siemens second-hand equipment + SIMATIC S5 + SITOP power supplies + 6EV / 6EW models + Used power supplies + SITOP PDF files

External References

Siemens ST 53 manufacturer catalogue – original file hosted by ADEGIS

6EV2031-4FC00 listing and manufacturer nameplate photograph – Happy Parts

Full-order-number spare-parts record – Allmendinger