Siemens 6EV1334-4AK00 Power Supply — 110/230 V AC, 24 V DC / 10 A
Siemens 6EV1334-4AK00 is an external power supply listed in the SINUMERIK 880 manufacturer manual, with 110/230 V AC mains connection and a 24 V DC / 10 A output. The document writes the code as 6EV1 334-4AK00. When replacing this power supply in a Siemens automation installation, check the complete code together with the existing mains connections.
Our site lists this item under Siemens 6EV / 6EW models and SITOP power supplies. After the general information in About Siemens SITOP, use the unit’s own connection drawing. Do not assume that this older supply has automatic input selection, electronic protection or parallel-operation features associated with modern supplies.
Electrical Ratings and Mains Selection
The nominal output is 24 V DC, 10 A. These ratings give a calculated output power of 240 W, not input consumption. Assess output voltage together with load current. Do not assign unverified percentage limits for regulation, no-load voltage or ripple.
Mains voltage selection uses terminal jumpers. The manual provides separate connections for 110, 120, 220 and 240 V. For example, its 220 V row specifies input at 1U3–2V2 and a 2U3–1V2 jumper; its 240 V row specifies input at 1U1–2V2 and a 2U1–1U3 jumper. These are the manufacturer drawing’s connections; compare them with the installed unit’s label and terminal markings before use. Change jumpers only with power isolated.
Connections and Load-Circuit Checks
Trace the mains input, DC output and chassis connections separately. Select cables, terminals and power supply accessories for the load current, and check protective grounding and DC returns against the machine diagram. Photographing jumpers and wiring before removal makes later comparison easier.
If the output falls or interrupts, inspect the supplied circuit first. Relay coils, wiring losses and a load-side short circuit can stress the supply. Find the cause of a blown fuse instead of increasing its rating. Two supplies marked 24 V can differ in current capacity and connection arrangement.
Bench and Load Test Suggestions
After isolation and verification that capacitors have discharged, begin with visual inspection and multimeter checks. Inspect winding continuity, rectifier connections and obvious short circuits. A single resistance measurement cannot establish winding insulation condition or the unit’s load capability.
Once the correct connections are confirmed, increase the load in controlled steps. At 24 V, a 2 A load represents about 48 W; 5 A represents 120 W. Use Ohm’s law to calculate the load, with adequate power and cooling margin. Full 10 A testing requires suitable load equipment. Record mains voltage, output voltage, current and temperature together, and examine voltage fluctuations with appropriate measurement techniques. A single no-load voltage reading does not complete the test.
Editor’s Note
Start with the input jumpers. Do not connect the unit to mains power before establishing how it was configured in its previous machine. When changing the supply arrangement, check every jumper, terminal and output polarity; the “24 V” marking alone is insufficient.
If there is no output, do not immediately condemn the transformer. With power isolated, inspect power diodes, connections, fuse holders and heat-stressed terminals. If a rectifier device has failed, inspect the connected load as well. These are general repair suggestions, not confirmed recurring faults for this model.
Older capacitors can look healthy despite deterioration. Assess capacitance, ESR and leakage together, and preserve the required voltage, temperature and ripple-current characteristics when replacing them. A normal DC reading can coexist with increased ripple; repeat measurements under load before returning the unit to service.
If voltage falls as the load increases, measure mains stability and terminal losses at the same time. Compare the supply output with the point where the load receives power. Do not change voltage connections at random to compensate for a loose contact; the fault may be outside the supply.
When buying a used power supply, request clear photographs of the complete code, input jumpers, terminals and housing. A test record should state the mains voltage, applied current and operating duration. “It produced voltage at no load” does not establish healthy operation at 10 A.
OtomasyonAVM Resources and PDFs
Siemens SITOP files is our common document page. The Siemens manual below includes the exact 6EV1334-4AK00 code.
+ Siemens SINUMERIK 880 — Connection Conditions, English PDF; 05.1991, 218 PDF pages. Connection drawing: PDF page 140 / printed 6-1. Output rating: PDF page 177 / printed 7-7.