6ES7 123-1FB00-0AB0
Siemens 6ES7 123-1FB00-0AB0 – ET 200L-SC 2 AI U Analog Input Module
The 6ES7 123-1FB00-0AB0 is a two-channel analog voltage input submodule for ET 200L-SC distributed I/O systems in the Siemens ET 200 family. Siemens identifies it as 2 AI U: “2 AI” indicates two analog input channels, while “U” identifies voltage measurement.
The module measures voltage signals from suitable sensors or transmitters and converts them into numerical values that the station can transfer to the main PLC. The sensor output and the selected input range must match before a pressure, level, position or other process value can be interpreted correctly.
Technical specifications
| Order number | 6ES7 123-1FB00-0AB0 |
| System / module type | ET 200L-SC / 2 AI U electronic submodule |
| Inputs | 2 analog voltage inputs |
| Selectable ranges | ±10 V and 1–5 V |
| Resolution | 13 bits for ±10 V; 12 bits for 1–5 V, including overrange |
| Input resistance | 100 kΩ for both voltage ranges |
| Electronics supply | 24 V DC nominal; maximum current consumption 30 mA |
| Typical power loss | 0.6 W |
| Dimensions / weight | 10 × 64 × 51 mm; approximately 20 g |
The supply voltage and the measurement signal are different. The 24 V DC specification is the supply for the module electronics; it is not the analog measurement range. Do not connect a 24 V supply or control signal to the analog input terminals.
Which analog signals can be measured?
Each channel can be configured for ±10 V or 1–5 V. For example, one channel may read a suitable pressure transmitter while the other reads a compatible level transmitter. Configure each channel for its actual sensor signal. The pages on analog inputs and analog inputs and outputs explain the general principles.
A 0–10 V output sensor can be read with this module by selecting the ±10 V range, since 0–10 V lies within its positive half. The module should not be assumed to have a separate selectable “0–10 V” range. The PLC program must scale the values corresponding to 0 V and 10 V for the actual process.
4–20 mA is a current signal. This product has voltage inputs; a 4–20 mA output cannot simply be connected and read as if the module had a current input. Select a suitable current input module or an appropriate current-to-voltage conversion solution. Check the transmitter supply, wiring arrangement and converter output range before making the selection. See also 0–10 V and 4–20 mA signals.
Pt100 sensors, thermocouples and load cells cannot be connected directly merely because they are analog devices. They require a suitable sensor input module or a transmitter with an output compatible with this voltage input. The distinction between analog and digital inputs is also useful when selecting the correct hardware.
PLC raw values and scaling examples
The module's raw number is not automatically a value in bar or metres. The PLC program converts it into engineering units using the selected range and the sensor's measurement scale. The examples below show ideal nominal values for the SIMATIC S7 data format; actual readings are affected by resolution, tolerance and signal conditions.
With the ±10 V range: 0 V corresponds approximately to raw value 0, +5 V to 13824 and +10 V to 27648. For a linear transmitter scaled as 0–10 V = 0–10 bar, 5 V therefore represents approximately 5 bar when the PLC scaling is correct.
With the 1–5 V range: 1 V corresponds approximately to raw value 0, 3 V to 13824 and 5 V to 27648. With this range selected, 0 V is outside the nominal measurement range. If the S5 format or a special configuration is used, check the applicable value representation separately.
During startup before the first conversion, or under certain out-of-range and supply conditions, a special value such as 7FFFh / 32767 may appear. It should not automatically be treated as a real process measurement; assess it against the relevant status and measurement-range tables in the manual.
Terminal block and station arrangement
This product is not a standalone PLC or an independent PROFIBUS station. It is installed in a compatible ET 200L-SC terminal block and station arrangement. The Siemens manual describes TB 16SC and TB 16IM-SC terminal arrangements for SC electronic modules.
TB 16SC is used as an expansion in a suitable ET 200L-SC station. TB 16IM-SC is used together with the appropriate IM-SC interface module. Screw and spring terminal versions exist, so check the complete order number of the existing terminal block before replacement. See the general categories for ET 200 connection modules and additional modules.
The terminal arrangement provides positions for up to 8 SC electronic modules. Although this 2 AI U submodule has two input channels, it occupies one module slot. The physical module order and station configuration must match the PLC project.
Connections and wiring
In the Siemens block diagram, the input channels are identified as M0+ / M0− and M1+ / M1−. Determine the physical terminal numbers from the manual for the installed slot and terminal block. Check the sensor's signal, reference and supply connections against its own wiring diagram.
The two channels must not be assumed to be galvanically isolated from one another. When connecting sources with different supplies or reference potentials, check the permitted common-mode voltage and grounding arrangement. The Siemens data sheet specifies a permitted potential difference between the inputs and analog reference of 2 V DC / 2 Vpp AC.
Use shielded signal cable and route analog wiring with suitable separation from motor and power cables. Connect the cable shield and grounding according to the plant EMC arrangement and Siemens instructions. Safely isolate the relevant supplies before changing connections. The analog voltage page provides further background.
Parameters, conversion time and filtering
In Siemens' default settings, both channels use the ±10 V range, 50 Hz interference suppression and no smoothing. If the installed sensor needs another range, configure the measurement range and other parameters accordingly. Measurement range and smoothing are selected per channel; interference-frequency suppression is selected for the module.
The data sheet gives a basic conversion time per channel of 65 ms with 50 Hz suppression and 55 ms with 60 Hz suppression. These numbers alone are not the total update time shown on the PLC display: the module cycle, communication and PLC program also affect the overall delay.
Smoothing can be set to none, weak, medium or strong. Stronger filtering can reduce fluctuations but increases the time taken for the displayed value to respond to a change. Select the filter with the process response time in mind.
Communication and troubleshooting
The analog submodule has no independent PROFIBUS connection. Data is exchanged through the interface of the ET 200L-SC station. Check the PROFIBUS network, station address and module arrangement in the PLC project together. The main controller may, for example, be a suitable S7-300 system.
The Siemens data sheet specifies no separate alarm or diagnostic function for this submodule. Station interface indicators and PLC diagnostics should be assessed separately; an interface LED should not be assumed to directly identify a broken wire on this analog channel.
If a value is incorrect or unstable, check the sensor supply, actual voltage at the input terminals, cable and reference connections, selected measurement range and PLC raw value. If the raw value is correct but the value shown on the operator panel or SCADA system is wrong, inspect the scaling and engineering units.
Editor's Note: Start by identifying the sensor output. A 0–10 V sensor can be used with the ±10 V setting and correct scaling; a 4–20 mA sensor is not connected directly as a current input. When replacing the module, check the complete order number, terminal block, channel parameters and PLC raw-value scaling together. This helps prevent incorrect measurements even when the replacement module is sound.
Manuals and related topics
For installation, wiring diagrams, parameters and analog value representation, visit Siemens ET 200 manuals and PDF files. For general system information, see About Siemens ET 200 and ET 200 communication modules.
Related topics: Analog-to-digital conversion · Analog signal applications · Analog signal controllers · S7-300 analog modules
Navigation: Siemens automation · SIMATIC S7 · Siemens ET 200 · OtomasyonAVM homepage