6ES7 193-1CL10-0XA0
6ES7193-1CL10-0XA0 Siemens ET 200L TB 32L Spring-Terminal Block
Siemens 6ES7 193-1CL10-0XA0 is the 32-channel TB 32L terminal block with spring connections for ET 200L stations in the SIMATIC ET 200 family. Field wiring terminates on this base, while a compatible electronics block fits onto it. This separates the permanent wiring from the electronics that process the signals within the ET 200 station assembly.
This terminal block is relevant when replacing an existing wiring base or assembling a station with suitable ET 200L electronics. Identify the complete order number of both components before selecting a replacement.
Specifications and dimensions
6ES7193-1CL10-0XA0 has spring terminals, a 32-channel arrangement and the system designation TB 32L / ET 200L. Siemens specifies a width of 191 mm, height of 100 mm, depth of 40.5 mm and approximate weight of 350 g.
Cabinet planning must also allow for the electronics block, bus connector and any supplementary terminal. Include space for cable bends and access during removal or installation. The dimensions of the bare terminal block do not describe the clearance required by the complete wired station.
Compatible electronics blocks
The TB 32L compatibility section in the Siemens ET 200L manual lists 6ES7131-1BL01-0XB0 for 32 DI, 24 V DC; 6ES7132-1BL00-0XB0 for 32 DO, 24 V DC / 0.5 A; and 6ES7133-1BL01-0XB0 for 16 DI / 16 DO, 24 V DC / 0.5 A. These are documented combinations. Check the applicable compatibility information when working with another revision.
The fitted electronics determine whether the station provides digital inputs, digital outputs or mixed I/O. The 0.5 A output rating belongs to the relevant electronics block; it is not a general current rating for every connection on the terminal base.
Terminal numbering and power connections
On TB 32L, terminals 1–32 carry the field signals. The purpose of terminals 33–64 depends on the electronics: they provide sensor supply connections for inputs and M connections for outputs. When changing from input to output electronics, do not assume that an unchanged terminal number means an unchanged electrical function.
The manual identifies separate supply connections for the electronics and channel groups. Terminals 1M–5M are internally connected; PE has a separate connection. Account for this common M arrangement when reviewing the supply groups. Select the power supply, circuit protection and field loads using the electronics block’s specifications together with the machine wiring drawings.
For an inductive sensor, identify the supply, common and switched signal separately. Compare the sensor wiring diagram with the terminal numbers instead of relying on cable colour or an old label. This is particularly useful on machines that have already been repaired or rewired.
Mounting and conductor preparation
The terminal block mounts on a 35 mm DIN rail. Siemens gives a conductor range of 0.14–1.5 mm² for the applicable connections. Its spring-terminal instructions specify an 11 mm stripping length and describe opening the spring with a suitable screwdriver. Where ferrules are used, their shape and length must also meet the manufacturer’s requirements.
Isolate the relevant circuits before installation. Check that the rail catches engage, conductors are inserted fully and no bare copper remains exposed. Position DIN rail power supplies and cable ducts so that the front connections remain accessible. Screw-terminal tightening torque does not apply to the spring connections on this version.
Related versions and supplementary terminals
6ES7193-1CL00-0XA0 is the screw-terminal version of TB 32L. The 6ES7193-1CL10-0XA0 covered here uses spring terminals. The 6ES7193-1CH10-0XA0 TB 16L is a different, 16-channel base. Check the CL/CH and 00/10 portions of the order number when identifying a part.
Additional connection points can be provided by the 6ES7193-1FL50-0XA0 single-tier spring supplementary terminal or the 6ES7193-1FL60-0XA0 two-tier spring supplementary terminal. These attach to the main terminal block. Connections within each supplementary-terminal tier are internally linked, which must be considered when planning the potential distribution.
Maintenance and fault finding
ET 200L field wiring stays on the terminal base when the compatible electronics block is removed. This avoids disconnecting each field conductor for an electronics replacement. Replacing the terminal base itself requires the wire identification and terminal assignments to be recorded first. Burn marks, a loose conductor, a damaged spring or a broken retaining feature can point to a connection problem that replacing the electronics alone will not resolve.
The electronics block handles data exchange with the PLC over PROFIBUS. TB 32L carries the wiring and electrical connections. If a channel is not operating, check the field device’s supply, terminal contact and signal before assessing the electronic channel status and station diagnostics.
Manuals and technical documentation
For terminal assignments, electronics compatibility and wiring requirements, use the Siemens ET 200 user manuals and PDF documents page. Match the ET 200L / TB 32L section to order number 6ES7193-1CL10-0XA0. For mixed input/output electronics in particular, follow the terminal assignment drawing for the exact electronics block.
Editorial note: Terminal numbering from 1 to 64 does not mean that TB 32L provides 64 independent I/O channels. It is a 32-channel base; the second row’s function depends on the input or output electronics fitted. Check the terminal number, electrical function and electronics order number together when replacing parts.
Related topics
Station components: ET 200 terminal blocks · connection modules · additional modules and accessories · power distribution components · power supply modules
Signals and communication: digital input modules · digital output modules · ET 200 communication interfaces · What is a PLC?
Technical references: Siemens 6ES7193-1CL10-0XA0 data sheet, 17 March 2017; ET 200L system manual, EWA-4NEB 780600901-05, section 7.2; ET 200L, ET 200L-SC and ET 200L-SC IM-SC manual, EWA 4NEB 780 6009-02c, installation, wiring and TB 32L sections. Related-topic links do not establish direct parts compatibility between different ET 200 subfamilies.
Navigation: Siemens Automation · Siemens S7 PLC · SIMATIC S7 · Siemens ET 200 · ET 200 manuals