6ES7 153-3AA01-0XB0

6ES7 153-3AA01-0XB0 is the Siemens IM 153-3 redundant PROFIBUS DP interface module for SIMATIC ET 200M. It connects up to 8 compatible S7-300 signal modules to the higher-level control system and provides two PROFIBUS connections for redundant communication. The control program runs in the higher-level PLC, while the IM 153-3 transfers field data between the ET200 station and the control system.

Product Description and Redundant Operation

The IM 153-3 contains two PROFIBUS interface sections within one assembly. In a suitable redundant system, they connect to separate DP master networks, with one channel active and the other available to take over. This arrangement helps maintain operation following a communication-path or controller-side fault. For network fundamentals, see PROFIBUS and PROFINET explained.

Redundancy requires coordinated master configuration, station configuration and switchover behaviour. Connecting two cables does not complete the system design. During maintenance, verify that the standby path is ready as well as checking the active connection. Other arrangements are covered in the Siemens communication interfaces section.

Technical Data

Manufacturer: Siemens
Product family: SIMATIC ET 200M
Order number: 6ES7 153-3AA01-0XB0
Module designation: IM 153-3
Function: Redundant PROFIBUS DP interface
PROFIBUS interfaces: 2
Physical interface: RS-485
Transmission rate: Up to 12 Mbit/s
Signal-module capacity: Up to 8 compatible S7-300 modules
Rated supply: 24 V DC
Permitted supply: 20.4–28.8 V DC
Current drawn from 24 V: Maximum 500 mA
Dimensions, W × H × D: 80 × 125 × 130 mm

The 8-module capacity is not the number of physical input or output channels. Channel counts and signal types depend on the installed cards. Check the complete signal-module order numbers alongside the interface when assessing a replacement.

Signal Modules and Station Compatibility

Field sensors and controlled loads connect through suitable signal modules. Depending on the application, these may include digital input modules, digital output modules and analog input modules. These categories contain different ET200 families, so verify suitability for the S7-300 / ET 200M arrangement and the installed interface version.

When replacing modules in an older installation, function alone may not establish compatibility. Hardware revision, parameter length, module sequence and project addressing can also matter. A card performing the same general task may require engineering changes before it can be used.

Installation, Supply and Bus Connections

Allow access to the front cover, PROFIBUS connectors and mounting points when planning the cabinet layout. Suitable panel components and organised cable routing make subsequent maintenance easier. Include the station’s bus and connection modules in the equipment record.

Check the cabling, shielding and termination of each PROFIBUS segment separately. Verify PROFIBUS suitability when selecting cables and connectors. Clear labels help prevent the wrong connection being removed, particularly where the two paths look similar.

Measure the 24 V DC supply at the module terminals under operating load. Include the other station components and field loads when assessing power supply capacity. The condition of the DIN-rail power supply and distribution wiring is also relevant when investigating intermittent communication faults.

Configuration and Commissioning

Use a hardware configuration appropriate to the IM 153-3 and its actual product version. Check the selected GSD file when working with STEP 7, COM PROFIBUS or another configuration environment. Siemens’ configuration and parameter-assignment frame document explicitly includes 6ES7 153-3AA01-0XB0; it is particularly useful when detailed telegram analysis is required.

Before replacement, retain project backups from both master systems, station addresses, module sequence and diagnostic records. Assess each communication path separately during commissioning. If a planned switchover test is required, establish the machine state and expected output behaviour beforehand and follow the installation’s maintenance procedure.

LED Indicators and Troubleshooting

SF: Group fault.
BF1 / BF2: Fault indicators for the respective PROFIBUS channel.
DP1 / DP2: Active-channel and data-exchange indicators.
ON: Supply indication.

Interpret the indicators together. The active channel may continue exchanging data while the other channel has a fault. Production can therefore continue with reduced redundancy. Comparing the relevant master’s diagnostic information with the interface indicators helps identify where the problem originated.

Determine whether the fault affects one network, both networks or a particular signal module. Identify the active path and standby status before removing a cable or interface section. Decisions about replacement during operation must account for the hardware arrangement, installed modules and manufacturer procedure.

Successor Product and Related Topics

Siemens’ product record lists 6ES7 153-2BA10-0XB0 as the successor. Migration from IM 153-3 to a redundant IM 153-2 arrangement requires two IM 153-2 modules, suitable active bus modules and configuration changes. Plan the migration after reviewing the complete station.

For comparison, see 6ES7 153-2BA00-0XB0, 6ES7 153-2BA01-0XB0 and 6ES7 153-2BA02-0XB0. These links provide product-family context and do not establish direct interchangeability.

Practical Selection Notes

For a spare-part enquiry, provide front and side label photographs, both PROFIBUS sections and the station base. Clarify whether the quotation covers the complete interface assembly or an individual subassembly. For used equipment, confirm the inclusion of covers, terminals, fixing screws and bus connections.

Review the test scope together with the stated product condition. Power-up, communication through one channel and testing in a complete redundant arrangement are different checks. When describing an existing fault, include the active channel and LED indications so that the situation can be assessed more accurately.

User Manuals and Technical Documents

+ Siemens ET200 PLC User Manuals — PDF archive page.

+ Siemens ET 200M Manual — July 2000 Edition Covering IM 153-3 — external document viewer; sections 2.7, 5.2, 7.3 and 8.4 are particularly relevant to this product.

+ Siemens ET 200M Configuration and Parameter Assignment Frames — technical PDF covering IM 153-3, order number 6ES7 153-3AA01-0XB0.

+ Siemens Software Redundancy for S7-300 and S7-400 — an externally hosted manufacturer document for legacy applications using IM 153-3.

+ Siemens ET200 General Catalogue — general product-family reference.

++ Siemens Automation Main Page >
++ Siemens Product Enquiries — contact Otomasyon AVM.
++ About Siemens ET200 PLC Systems >

Reminder: Confirm current availability, condition and delivery contents with Otomasyon AVM for the Siemens 6ES7 153-3AA01-0XB0 and other SIMATIC products. Some items are used equipment; take this into account before purchasing. Products will not be restocked once sold out. This page provides general information; check the product label, hardware version and applicable manufacturer documentation for your installation.

Note: Manuals, commissioning suggestions and troubleshooting descriptions are provided for reference and are not binding. Content may be updated or expanded. The Otomasyon AVM Community welcomes practical feedback. You can share your operating and maintenance experience with us.

Technical references: Siemens 6ES7153-3AA01-0XB0 product record; ET 200M Distributed I/O Device, July 2000, EWA 4NEB 780 6006-02 04; ET 200M Configuration Frame and Parameter Assignment Frame, A5E00190342-03.