6ES7 153-2BA00-0XB0
6ES7 153-2BA00-0XB0 is a Siemens IM 153-2 High Feature interface module for the SIMATIC ET 200M distributed I/O system. It connects compatible S7-300 modules to PROFIBUS DP and supports a maximum of 8 modules. Its functions include redundancy, time stamping and isochronous operation. Related interfaces are available in our ET200 PROFIBUS and PROFINET section.
Device Description
The module handles communication between the central control system and an ET 200M station. The control program runs in the upstream PLC, while station input and output data passes through the IM 153-2. This allows compatible S7-300 I/O hardware to serve equipment at different locations within a machine or plant. Our Siemens ET200 product range provides an overview of the wider family.
When selecting a replacement, the designation “IM 153-2” alone is insufficient. Check the 2BA00 order-code section, hardware revision, installed backplane and configured device entry together. Understanding the differences between PROFIBUS and PROFINET also helps identify the appropriate interface family.
Technical Data
Manufacturer: Siemens
Order Number: 6ES7 153-2BA00-0XB0
Designation: IM 153-2 High Feature
System: SIMATIC ET 200M
Station Capacity: Maximum 8 compatible S7-300 modules
Communication: PROFIBUS DP, RS-485
Transmission Rate: Up to 12 Mbit/s; automatic rate detection
PROFIBUS Addresses: 1–125
Rated Supply: 24 V DC
Supply Range: 20.4–28.8 V DC
Current Consumption: Maximum 550 mA at 24 V DC
Backplane Supply: 5 V DC, maximum 1 A
Typical Power Loss: 5 W
Address Space: 128 input bytes / 128 output bytes
Dimensions: 40 × 125 × 117 mm — width × height × depth
Protection: IP20
Redundancy and Timing Functions
Redundant operation: Two compatible IM 153-2 interfaces, a BM IM/IM and active bus modules can form a redundant station. The upstream controller must support this arrangement. Installing a single interface does not provide station redundancy.
Time stamping: Digital input transitions can be recorded with time information. The documentation specifies 10 ms / 3 ms accuracy classes and 1 ms time resolution. Resolution does not equal accuracy; the achievable performance also depends on the input module and time synchronization arrangement.
Isochronous operation: For the 2BA00 from revision E01, Siemens specifies equidistant cycles of 0.625 ms or longer with STEP 7 V5.2 or GSD revision 4. Compatible master and I/O hardware are required. Active bus modules introduce a slot-dependent timing offset, so the physical station arrangement must be considered.
Installation and Commissioning Recommendations
Record the existing installation: Before replacement, note the module label, PROFIBUS address, slot sequence and project version. In an older cabinet, the latest wiring changes may not appear in the original drawings. Keeping label photographs with the hardware configuration makes subsequent maintenance easier.
Check the supply under load: Size the power supply for all relevant consumers, rather than using the interface consumption alone. When reviewing DIN rail power supplies, distribution wiring and control cabinet components, measure the voltage at the station as well as at the supply terminals.
Identify the backplane: Record the exact part numbers of the installed connection modules. A standard assembly and a station with active bus modules have different maintenance requirements. Before replacement during operation, verify the hardware combination and follow the applicable manufacturer procedure.
Compare the project with the station: The configured device, PROFIBUS address and module sequence should match the physical installation. When using a GSD-based configuration, confirm that the file covers this revision. After communication is established, monitor representative inputs and outputs to verify address mapping.
LED Indicators and Troubleshooting
ON — Green: Supply indication.
BF — Red: PROFIBUS fault indication.
SF — Red: Group fault indication.
ACT — Yellow: Identifies the active interface in redundant operation.
Read the indicators as a combination. Their meaning can change during startup, firmware updating and normal operation. Record whether each LED is steady or flashing, then compare that observation with the online diagnostic information. A photograph or short video can help preserve an intermittent indication for later analysis.
If communication fails during a particular machine movement, inspect the supply and cable routing while that event occurs. If the problem affects only one field signal, check the associated sensor, channel wiring and cables and connectors separately. Distinguishing a station fault from a field-channel fault can prevent unnecessary interface replacement.
Editor's Recommendations
Keep a complete spare-part record: Store the order number, hardware revision, bus-module identification and working project backup together. For a redundant station, photograph both interface labels individually. This provides a much stronger basis for purchasing than appearance or family name alone.
Assess later revisions separately: 6ES7 153-2BA01-0XB0 and 6ES7 153-2BA02-0XB0 are different revisions within the family. The BA02 generation's 12-module capacity and expanded I/O features should not be assigned to the BA00.
Siemens identifies 6ES7 153-2BA10-0XB0 as a successor. Check project, firmware and redundant-pair compatibility before making a replacement decision. Stations using the older IM 153-3 interface require a separate assessment of their installed hardware arrangement.
Related Topics
For field-signal product research, browse our ET200 digital input modules, ET200 digital output modules and ET200 analog input modules. These categories include several ET200 subfamilies; compatibility with ET 200M and the installed configuration must be checked individually.
Manuals and Technical Documents
+ Siemens ET200 User Manuals — PDF archive page
+ Siemens ET 200M Operating Instructions — includes 6ES7 153-2BA00-0XB0; English PDF
+ Siemens ET200 General Catalogue — general product-family PDF
Technical sources: Siemens model data sheet, earlier ET 200M system manual and Siemens product information describing BA02 generation changes. The first two links are manufacturer documents hosted externally.
++ Siemens Automation Main Page >
++ Siemens Automation Contact — for Otomasyon AVM
++ About Siemens ET200 PLC >
Reminder: Please confirm current availability, condition and delivery scope for Siemens 6ES7 153-2BA00-0XB0 and other SIMATIC products with Otomasyon AVM. Some devices are used products; take this into account when purchasing. Products will not be restocked once sold out. This page provides general information; the product label, hardware revision and applicable manufacturer documentation should govern your application.
Note: Manuals, commissioning recommendations and troubleshooting explanations are non-binding and may be updated or improved. The Otomasyon AVM Community welcomes practical experience. You can share your operating and maintenance recommendations with us.