6ES5 948-3UA12

Siemens 6ES5 948-3UA12 CPU 948 — S5-155U, 640 KB RAM

The Siemens 6ES5 948-3UA12 is a CPU 948 processor for S5-155U with 640 KB of internal user RAM. In a SIMATIC S5 system, 6ES5 948-3UA12 executes the user program, processes application data and controls the peripherals. This processor in the Siemens S5 PLC family uses STEP 5 programs.

CPU 948 supports single-processor and multiprocessor operation in a suitable central-controller configuration. Program processing can be cyclic, time-controlled or interrupt-driven. Select a replacement by its complete order code, hardware version and application requirements, as well as the CPU 948 designation.

Memory and program resources

640 KB RAM is the internal user memory for this order code. The CPU 948 technical table specifies 256 timers, 256 counters, 2048 flags and 32768 S flags. The process image supports up to 1024 digital input signals and 1024 digital output signals; these capacities do not indicate physical I/O terminals on the CPU.

A Flash EPROM memory card can store the user program and data. S5 memory cards include different capacity and technology codes, such as 6ES5 374-2KH21 and 6ES5 374-2KL21. Verify card selection against the CPU version, program size and programming equipment.

An Overall Reset reinitializes internal RAM and erases its existing data; if a memory card is present, its contents are copied into RAM. The card may not contain the latest version running in the machine. Preserve the current program, data blocks and machine parameters before the operation to avoid data loss.

Rack, supply and mechanical construction

This CPU 948 construction occupies two slots. Dimensions are 40.6 × 233.4 × 160 mm, with an approximate weight of 1 kg. When reviewing central-controller records such as 6ES5 188-3UA11, check the actual rack version and CPU arrangement.

The manual specifies a 5 V ±5% supply, 3.6 A typical consumption at 5 V and a 3.4 V backup voltage. Assess the S5 power supply against the combined load of the CPU and other modules. The protection rating is IP00, requiring installation in a suitable rack and cabinet.

The CPU's two interconnected circuit boards form one assembly; Siemens states that they must not be separated. Insert or remove the CPU only with the power supply switched off. Do not alter factory test jumpers arbitrarily.

SI1, SI2 and PG connection

SI1 is the front 15-pin PG connection, with a specified serial PG transmission rate of 9600 bit/s. The second interface, SI2, can operate as a PG interface with a suitable submodule. Among S5 interface modules, the 6ES5 752-0AA53 PG submodule is documented for CPU 948; this PG submodule uses 20 mA current-loop signals.

Verify the electrical interface when selecting PG cables and connectors. The CPU's PG interface can also be accessed through a 923C coordinator and the S5 bus. The manual states that the front connection and coordinator path to this same PG interface must not be operated simultaneously.

RUN, STOP and fault LEDs

RUN indicates program execution, STOP indicates soft STOP and SYS FAULT indicates hard STOP. QVZ relates to acknowledgement or timeout faults, ADF to addressing faults, ZYK to cycle-time monitoring and BASP to command-output inhibition. Interpret the LEDs alongside diagnostic information and the hardware expected by the program.

If no submodule is installed in SI2, an unlit SI2 fault LED alone does not establish that an interface is fitted and working. Include actual PG communication and the installed submodule in replacement-unit checks.

Related CPU codes and replacement checks

6ES5 948-3UA11, 6ES5 948-3UA13, 6ES5 948-3UA21, 6ES5 948-3UA22 and 6ES5 948-3UA23 are different CPU 948 order codes. The family includes 640 KB and 1664 KB memory versions and different hardware constructions. Even where memory capacities match, compare installation, consumption and version requirements separately.

Review program and system requirements when changing between CPU 928B and CPU 948. 6ES5 948-3UR21 CPU 948R is a separate model associated with S5-155H applications and must not be assumed to be a direct UA12 replacement.

Editor's Note

Ask for a clear photograph of the complete CPU label and version information. This code is the 640 KB 3UA12; “we have a 948” is not enough. Compare the two-slot housing and the arrangement of neighbouring modules as well.

Back up the running machine through the PG first. A fitted Flash card does not establish that it contains the latest program. Treating Overall Reset as a test button can lose changes held only in RAM.

A STOP or QVZ indication does not immediately prove a faulty CPU. Check whether the expected module is installed, correctly addressed and responding. Record LED states and diagnostic information before clearing anything.

Check supply and cooling together. Typical consumption for this construction is 3.6 A on the 5 V rail; a weak power supply or poor contact can make a sound CPU appear faulty. Do not separate the two interconnected boards or change jumpers at random.

Ask for more than “it goes into RUN”: include PG communication, program reading and operation with a suitable test project. If SI2 is needed, confirm that the correct submodule is physically fitted. Record the rack and version used for testing.

OtomasyonAVM resources and PDF documentation

Use About Siemens S5 PLC for system information and the Siemens S5 PDF archive for documentation. Establish the exact model and memory description from the Siemens 6ES5948-3UA12 data sheet, and assess the older two-slot CPU 948 hardware using S5-135U/155U System Manual, C79000-G8576-C199-07, section 5.2.

Related topics

6ES5 948-3UA11 · 6ES5 948-3UA13 · 6ES5 948-3UA22 · 6ES5 752-0AA53 PG submodule · S5 memory cards

Navigation: 6ES5 948-3UA12 model page | SIMATIC S5 main page | Siemens S5 PLC models | S5 interface modules | Used Siemens products

Siemens documents and external references

Siemens S5-135U/155U System Manual — English PDF: section 5.2, printed pages 5-17–5-29; PG submodule in section 5.11.2. The later 3UA13/3UA23 hardware is covered separately in section 5.1.

Siemens 6ES5948-3UA12 data sheet — English PDF: exact code, S5-155U and 640 KB description; Siemens document hosted by SPS-Service.