6ES5 920-3UA12
Siemens 6ES5 920-3UA12 – CPU 920 M processor, S5-135U/155U
Siemens 6ES5 920-3UA12 is a CPU 920 M-processor central module in the SIMATIC S5 family. The CPU 920 was developed for measured-data processing, arithmetic, sorting and statistics. Siemens documents C, BASIC and Assembler programming for this processor family, making the application’s development environment an essential part of a Siemens S5 maintenance project.
Compare revisions with the 6ES5 920-3UA11 using complete labels. The CPU 921 S processor and CPU 922 R processor have different roles and programming arrangements. Similar CPU numbers do not establish direct program or hardware interchangeability.
Development environment and application backup
Identify the source code, compiler or interpreter version, runtime environment and loading method for the CPU 920 application. A PLC programming backup must cover the actual M-processor project. Record the installed programming software and available project files from the working system.
Inspect the complete code and contents of the fitted S5 memory module. Treat user code, working data and system software separately. Do not transfer RAM capacities or memory-socket specifications from CPU 921/922/928 tables to the 920-3UA12.
Single-processor and multiprocessor operation
Siemens multiprocessor documentation includes the CPU 920 family in S5-135U and S5-155U systems. Suitable configurations support up to four CPUs, each executing its own application. A 923A or suitable 923C coordinator arrangement manages shared S5 bus access. Verify coordinator and rack selection against the complete CPU configuration.
Establish which processor controls each digital input and digital output module from the existing address plan. Family documentation describes IPC flags for cyclic interprocessor data exchange and special multiprocessor communication functions with the 923C for transferring complete data blocks.
CPU 920 programmer-access distinction
The CPU 920 cannot be accessed through the 923C central PG multiplexer. Siemens explicitly identifies this exception in its multiprocessor documentation. Match the programming cable and interface hardware to the existing M-processor connection and loading arrangement.
Record the installed communications modules separately. A CP’s serial, Ethernet or fieldbus functions do not establish built-in CPU 920 ports. Preserve the application’s communication arrangement and startup sequence.
Rack, supply and revision checks
The multiprocessor layout table lists the CPU 920 family as requiring one CPU slot. Check the actual S5 rack layout and bus assignment. Inspect the S5 power supply, backup circuit and connectors together with the processor.
Diagnostics and used-unit checks
During PLC troubleshooting, verify application loading, calculation results, shared-data exchange and required I/O behaviour as well as processor startup. Do not directly apply CPU 921 or CPU 922 LED interpretations and memory-reset procedures to this model.
For a used PLC CPU, establish the complete 6ES5 920-3UA12 code, board revision, fitted memory and included software. When buying used Siemens equipment, clarify whether the scope covers only hardware or a recoverable application too.
Base model comparisons on the processor’s role and existing source code. If assessing Derell PLC options for modernization, separately redesign the M-processor calculations, data formats, communications and relationships with other CPUs.
Editor's Note
First identify the application running on the M processor. Obtain the relevant C, BASIC or Assembler files before assuming that replacing the board will restore the complete system.
Photograph the full 3UA12 code, board revision and memory labels. Do not assign specifications from a 3UA11 or neighbouring CPU 921 to this module.
If programmer access fails, check the connection method first. The CPU 920 is excluded from access through the 923C PG multiplexer. Inspect the existing cable, interface and loading environment together.
Preserve the source code, executable application and required runtime files together. Establish what each backup restores and which software version is needed.
A bench check should cover calculated values, data exchange with other CPUs and actual I/O results. Prepare backups before disconnecting power and remove the module only with power off.
OtomasyonAVM resources and PDFs
6ES5 920-3UA12 main page · Used Siemens S5 models · Siemens S5 PDF archive
Document scope: Programming, multiprocessor operation and PG-multiplexer information comes from Siemens CPU 920 family sections. A standalone technical sheet specific to 3UA12 was not verified, so exact RAM capacity, current, baud rate and dimensions are omitted. The CPU 921/922 manual below is used for its shared system sections concerning CPU 920; it is not presented as a dedicated 3UA12 operating manual.
Related topics
6ES5 920-3UA11 · 6ES5 921-3UA12 · 6ES5 922-3UA11 · 6ES5 923-3UC11 · Derell PLC options
Navigation
SIMATIC S5 · Siemens S5 models · Used Siemens · S5 memory modules · S5 racks
Siemens and external references
Siemens CPU 920 M processor – programming and S5-135U/155U family coverage, English
CPU layout and multiprocessor data exchange · CPU 920 exclusion from 923C central PG-multiplexer access
Historical UL component record in Siemens archive – 6ES5920-3UA1. central processor family, English