6ES5 756-0AA11

6ES5 756-0AA11 – SIMATIC S5-150U Jumpering and Bus Routing Card

Siemens 6ES5 756-0AA11 is the jumpering and bus routing card for the S5-150U central controller in the SIMATIC S5 family. Siemens identifies it as a Rangierkarte. In the documented standard configuration, it occupies slot 27; with solder jumper 11 on the backplane open, slots 3, 11 and 19 are configured for CP 5xx communications processors.

The numbers 3, 11, 19 and 27 identify physical chassis slots. When reviewing the S5 rack and backplane, keep these positions separate from PLC input/output addresses. The card establishes the electrical routing for the relevant slot group; its role differs from the data exchange performed by an S5 communications processor.

Slot 27 and solder jumper 11

The Siemens S5-150U manual shows the 756 card in slot 27 with jumper 11 open as the delivered configuration. In this arrangement, slots 3, 11 and 19 accept CP 5xx modules. These instructions apply to the S5-150U backplane described in that manual; matching slot numbers alone do not make them applicable to another S5 chassis.

Jumper 11 is on the central controller's backplane. The manual locates solder jumpers 1–11 on the solder side of that board. This is not an instruction to connect arbitrary pins on the 756 card. Record the chassis version, existing solder-jumper settings and installed module arrangement together.

Difference from the external-memory configuration

When an external-memory interface occupies slot 27, slots 3, 11 and 19 are configured for 340/350 memory modules. The 341 external-memory interface belongs to this alternative arrangement. Closing jumper 11 in that configuration specifically routes slot 3 for the external-memory parity module.

Consequently, physical fit alone is insufficient when installing S5 memory hardware and S5 interface modules in this area. The CP arrangement and the external-memory arrangement use different backplane configurations. Establish the purpose of the existing layout before replacing the 756 card with another module.

Associated S5-150U hardware

In the same system's spare-parts list, Siemens identifies central modules 1–4 as 6ES5 924-3SA11, 6ES5 925-3SA11, 6ES5 926-3SA11 and 6ES5 927-3SA11, respectively. These system components have roles distinct from the 756 jumpering card; appearing in the same list does not establish interchangeability.

The list also includes the 6ES5 955-3LF11 and 6ES5 955-3LF12 power supplies, the 6ES5 955-3NF11 DC supply option and the 6ES5 956-0AA11 15 V supplementary module. Identify these parts separately when reviewing the system's power and fan arrangement. Their input-voltage ratings are not external supply specifications for the 756 card.

Installation checks and fault assessment

The manual's layout drawing also identifies the 6ES5 511-5AA12 programmer interface as a separate module. Successful programmer access alone does not demonstrate correct operation of every CP slot routed through the 756 arrangement. When checking the SIMATIC S5 central system, assess card seating, backplane contacts, jumper 11 and the behaviour of the relevant CP modules together.

After replacement, perform controlled commissioning while preserving the existing program and hardware configuration. If faults affect only particular slots, first check their intended function and backplane routing. Changing solder jumpers by trial and error can also disrupt a previously correct configuration.

Editor’s Note

When buying used Siemens equipment, do not mistake this card for a simple blanking plate. Ask for the 6ES5 756-0AA11 label, photographs of both sides and clear views of the edge connections. Preserving the correct connection arrangement matters more than cosmetic appearance.

Photograph the complete chassis before removing S5 modules. Record what occupies slot 27, which cards are in slots 3–11–19 and the state of jumper 11. Document the working arrangement before disturbing it.

Inspect this S5 accessory card for cracks, damaged tracks, corrosion and added wire links. Do not reproduce an old repair on the assumption that it is a factory connection. Use an identical known good card and the correct chassis manual as references.

Isolate power before removing or inserting the card. For continuity checks, disconnect it from the system and compare against verified documentation or a known good example. Do not create arbitrary shorts without knowing the intended connections.

In Siemens S5 maintenance, “the CPU starts” is an incomplete test result for this part. Check the relevant CP slots in the installed configuration and record the chassis type, jumper 11 state, installed CP order numbers and observed result. That gives the next technician a useful record instead of another assumption.

OtomasyonAVM resources and PDFs

For the installation layout, browse S5 racks and chassis, S5 accessories and S5 interface modules.

+ Shared SIMATIC S5 PDF and system manual archive. The German S5-150U manual covering this exact order number and slot configuration is linked in the external references below.

Related topics

+ 341 external-memory interface and S5 memory cards.

+ S5 communications processors and the 511-5AA12 programmer interface.

Browse SIMATIC S5

S5 accessories · S5 racks · SIMATIC S5 systems · Siemens S5 PLCs · Siemens second-hand equipment

Siemens and external references

Siemens SIMATIC S5 AG S5-150U Handbuch – 6ES5 998-0AL11, Edition 11 (German PDF). PDF p. 16: exact order number and standard layout; p. 18: slot 27, jumper 11 and CP/memory arrangements; p. 47: spare-parts list.