6ES5 695-0AA11
Siemens 6ES5 695-0AA11 – SIMATIC S5 External EPROM Programmer
Siemens 6ES5 695-0AA11 is an external EPROM programmer for SIMATIC S5 systems. Also known as a PROMMER, it was offered for PG 695 and AT-compatible PC environments. It provides the programming hardware needed to transfer programs to S5 memory modules.
Typical maintenance tasks include preparing a memory module for an S5 CPU and preserving program backups for older machines. Select the memory, adapter, connecting cable and software release together. Within the Siemens S5 family, similar-looking memories can differ in capacity and programming requirements.
PC connection and software selection
Siemens’ Working with S5-DOS/ST manual describes a serial PROMMER connection through the PC COM port; another COM port can be selected using S5DRV.EXE. Match the S5 connecting cable and interface to the device’s connection documentation. A connector that fits does not establish a correct pin assignment.
The STEP 5/ST V7.1 manual states that serial PROMMER support was discontinued. When selecting programming software, check the actual PC/PG installation, port access and PROMMER support together. Having a STEP 5 basic package for a PG 685 also does not establish compatibility with this programmer.
Memory order number, capacity and programming number
Read the complete 6ES5 order number on the memory first. For example, 6ES5 373-0AA41 and 6ES5 373-1AA81 are separate models. A similar housing or shared series prefix does not establish identical programming settings.
Other memories, including 6ES5 375-0LA11 and 6ES5 375-0LC31, also require individual checks of their order number, capacity and adapter requirements. These model links are not a verified compatibility list for 6ES5 695-0AA11. Confirm support by the actual programmer and installed software before proceeding.
The STEP 5 programming number identifies the memory type; an incorrect selection can damage the module. Before PLC programming, compare the displayed memory information with its label. Keep programming language selection separate from memory hardware programming settings.
Reading, backup and testing
Read an unfamiliar memory and save its contents before making changes. Then plan supported blank-check, writing and readback comparison operations. During PLC troubleshooting, preserve the only known good program copy. Include the file name, memory order number and test date in your PLC maintenance records.
Use a separate memory with confirmed compatibility to distinguish programmer faults from memory or cable problems. UV-erasable EPROMs and electrically erasable EEPROMs require different erasing methods. Check the memory’s own documentation before selecting an operation.
Used-unit and accessory inspection
When assessing S5 supplementary hardware, establish whether the cable, adapters and working software environment are included. The PG-MUX 757 provides access to different targets’ programming interfaces and serves a different purpose from an EPROM programmer. Match the purchase to the actual maintenance task.
Editor’s Note
Start by asking about the complete working setup: which PC, which software release and which cable were used? With used Siemens equipment, these answers are more useful than a clean housing alone.
Keep the machine’s only working memory out of the first trial. Read it, keep two separate backups and record which machine the files belong to. Preserve the sound copy while preparing a replacement.
A failed connection does not immediately prove a faulty programmer. Check serial PROMMER support in the software, then the port and cable. A newer software release is not automatically a solution for older hardware; release compatibility matters here.
Inspect the memory orientation, contacts and any adapter order number before insertion. Stop and check the combination if it does not seat correctly. Verify the programming number against the label and relevant assignment list instead of entering it from memory.
Ask for a read and write test using an identified memory, alongside the power-on demonstration. Record the memory and software release used. This gives the receiving workshop a practical starting point for repeating the test.
OtomasyonAVM resources and PDFs
+ Shared SIMATIC S5 PDF archive · S5 memory modules · S5 cables and connectors. The Siemens documents below cover software and connection arrangements; they do not replace the exact device manual.
Related topics
+ PLC programming · PLC troubleshooting · Programming software selection.
Browse SIMATIC S5
+ S5 supplementary modules and accessories · SIMATIC S5 · Siemens S5 PLC · Siemens second-hand main page.
Siemens and external references
+ Siemens STEP 5/ST V7.1, C79000-G8576-C920-04, English; section 2.4: serial PROMMER support; section 18.1: memory operations and programming numbers. This V7.1 reference is not a software compatibility recommendation for the device.