6ES5 516-3UA11

Siemens 6ES5 516-3UA11 — CP 516 Dual Memory Card Module

Siemens 6ES5 516-3UA11 is the CP 516 memory module for the SIMATIC S5 family. It provides two memory card slots; Siemens ST 50 lists a maximum total capacity of 8 MB. Actual capacity depends on the fitted memory cards; the rating does not establish that a used module includes cards providing 8 MB.

The module stores recipes, message texts and production data that do not need to remain continuously in CPU working memory. The manual addresses CPU-specific function blocks for S5-115U/H, S5-135U, S5-150U and S5-155U/H. In each installation, including S5-115U, distinguish the PLC program from the role of external data memory.

RAM, Flash and hardware revision

RAM and EPROM-based storage have different retention and programming requirements. Siemens specifies support for 5 V-only Flash cards from CP 516 hardware revision 2 onwards. When selecting Flash memory, compare the full card code and CP revision rather than treating physically similar cards with different programming voltages as interchangeable.

Selecting memory cards

Distinguish the retention behaviour of a 6ES5 374-2AH21 RAM card from 5 V Flash versions such as 6ES5 374-2KH21, 6ES5 374-2KK21 and 6ES5 374-2KL21. Record slot occupancy, card labels and the arrangement used by the existing application. Check suitability against the hardware revision and manufacturer’s card list.

RAM backup and battery protection

Removing the CP 516 from the rack is different from removing a RAM card from the CP 516. A serviceable CP battery can preserve data in fitted RAM cards when the module is removed. The manual states that the cards have no internal battery and lose their data when removed from the module. To prevent data loss, back up their contents before removal and check battery condition.

Supply and rack requirements

ST 50 specifies maximum 0.8 A at 5 V, maximum 5 W power loss and one rack slot. Check the S5 power supply budget and rack arrangement. Suitability of an S5 accessory for an existing installation depends on the CPU, chassis and mounting arrangement together.

Addressing and synchronization

CP 516 uses page-frame addressing. Hardware settings select one or four interfaces and the first interface number. The manual specifies F400H as the base address required by the standard EXT blocks and instructs users to retain the factory base-address setting. Following power restoration, each interface in use requires SYNCHRON; an unsynchronized interface accepts no requests. Compare these settings with the existing CPU project.

Function blocks and CPU data exchange

ST 50 identifies FB 199 for data transfer in the 115U/135U/155U group and DB 255 as its assigned workspace. Check the software environment, CPU-specific EXT package and handling blocks together. Record the existing interface configuration used for S5 communication; the same FB number does not establish that every CPU uses the same block file.

Controlled testing and diagnostics

During troubleshooting, check card type, battery condition, CPU blocks and the existing data arrangement first. Perform trial writes on a suitable backed-up test card rather than the only production copy. Verify card recognition, data reading and readback of written test data separately. Keep formatting and deletion commands away from the working archive until a verified backup exists.

Editor’s Note

For a used Siemens CP 516, inspect both slots. Buying the module does not establish that memory cards are included. Obtain clear card codes, capacities and the CP hardware revision.

Back up a RAM card before pulling it. The battery on the module cannot accompany a removed card. Do not lose the only recipe or production-data copy while checking whether the hardware works.

Treat a battery warning as a reason to inspect the contacts and any residue from the old battery as well. Follow the manufacturer’s backup and replacement procedure before interrupting the existing retention supply.

Record which card occupies A or B and what each contains before changing the arrangement. Preserve the production configuration when introducing a separate test card.

A CPU entering RUN is only part of a memory test. Check that data blocks or files can be read and that test data returns correctly. Back up first, then test deliberately; protect the stored data as carefully as the module.

OtomasyonAVM resources and PDFs

Browse the 6ES5 516-3UA11 model page and S5 memory cards for related equipment. The shared SIMATIC S5 PDF archive provides system documentation.

Siemens CP 516 Product Manual with standard function blocks — January 1998, English with German supplementary notes, 245 pages — 6ES5 998-1EB21. Hardware scope: revision 2 onwards; RAM backup: §1.4.7.

Related topics

+ 6ES5 374-2AH21 — RAM card

+ 6ES5 374-2KH21 — 5 V Flash card

+ 6ES5 374-2KK21 — 5 V Flash card

+ 6ES5 374-2KL21 — 5 V Flash card

Browse SIMATIC S5

+ 6ES5 516-3UA11 model page

+ S5 memory cards

+ S5 accessories

+ SIMATIC S5

+ Siemens second-hand equipment

Siemens and external references

+ Siemens CP 516 Product Manual, 6ES5 998-1EB21 — English

+ Siemens ST 50, 1998 — CP 516 technical specifications and ordering data, p. 4/95, English

+ Siemens ST 50 — FB 199 / DB 255 and CPU-specific block selection, p. 7/128, English