IC697MDL740
24/48 Volt DC, 2 Amp, 16-Noktalı Çıkış Modülü
16 çıkış noktası: Dört izole edilmiş 4 noktalı grup
2 amper kapasite her nokta için
Yüksek ani akım kapasitesi: Anma akımının 10 katı
The 24/48 Volt DC 2 Amp Output Module provides 16 output points divided into four isolated groups of 4 points each. Each group of four outputs is individually fused with a 10-amp fuse. The module supports a high degree of inrush current, making it suitable for a wide range of load types with such characteristics.
At the top of the module, there are LED indicators that display the ON/OFF status of each output point on the logic (PLC) side, as well as a separate LED to indicate the status of the fuse.
The module is mechanically keyed to prevent incorrect replacement with a different module type. I/O references can be configured by the user without the need for jumpers or DIP switches on the module.
Configuration is performed using the MS-DOS or Windows programming software that operates on Windows 95, Windows NT, and connects via Ethernet TCP/IP or through the SNP port. The configuration software is installed on the programming device, which can be an IBM XT, AT, PS/2, or compatible personal computer.
Çıkış Özellikleri:
Bu modül, aşağıdaki cihazlarla uyumludur:
Selenoidler
Motor yolvericiler
Gösterge cihazları
Each output point has a 2-amp current capacity. The module supports up to 4 amps per group of four outputs. Each output can handle surge currents significantly higher than its continuous rating, with repetition rates dependent on the device's current rating and duty cycle.
For typical incandescent devices at 50% duty cycle, the following repetition rates apply:
Steady-State Current (mA) Repetition Rate (Hz)
0.5 5
1 1
2 0.1
Hata Modu Seçimi:
The output points can be configured to respond to certain operating or default conditions by assuming one of two states:
Mevcut çıkış durumunu koru
Çıkışları KAPAT
For more detailed information, refer to the programming manual.
Sigorta:
Each group of 4 outputs is protected by a 10-amp fuse. When replacing the fuse, use one of the following types:
3AG - 10 amper, 250V, Hızlı Etkili
Metric 5 x 20 mm - 10 amper, 250V, Hızlı Etkili
Mekanik Anahtarlama:
The module includes a mechanical key that prevents the inadvertent substitution of another module type in the same slot. The key fits into a specific area on the module and remains latched to the backplane when the module is removed, ensuring that only identical module types can be inserted into the slot.
Alan Kablolaması:
The module is wired as shown. Each group of four outputs is isolated, and a wire from the power source to the power input terminals is required for each group (the power input terminals for each group are not connected inside the module). The terminal board supports wire sizes ranging from AWG #22 (0.36 mm²) to AWG #14 (2.1 mm²). Two wires of the same size can be terminated on one lug.
Teknik Özellikler:
Parametre Özellik
Anma Voltajı 24 veya 48 volt DC
Modüldeki Çıkış Sayısı 16 (Dört grup, her grup 4 çıkış)
Yalıtım 1500 volt (çıkıştan arka plana), 500 volt (gruplar arası)
Çıkış Voltaj Aralığı 20 ila 60 volt
Çıkış Akımı Nokta başına maksimum 2 amper, grup başına maksimum 4 amper
Ani Akım Maksimum 20 amper (20 ms boyunca)
Çıkış Voltaj Düşüşü Maksimum 0.8 volt (0.4 ohm)
Açma/Kapama Tepki Süresi Maksimum 2 ms
Kaçak Akım Maksimum 1 mA
5V Bus'tan Gerekli Akım 0.15 amper
This module supports VME system standard and complies with VME standard C.1.
>> GE Fanuc IC697MDL740 kullanım kılavuzları (pdf)
+ Ge fanuc 90-30 Plc diğer modüller
---
+ Ge-Fanuc 2 Ana sayfa
+ Ge-Fanuc ietişim (Otomasyon AVM için)
+ Ge-Fanuc Hakkında